DESCRIPTION
The fuel injectors are
solenoid operated valves. When a fuel injector solenoid is energized
(pulsed) the injector needle valve opens, allowing pressurized fuel to
pass through the injector and mix with air entering the
engine.
The Engine Control
Module (ECM) controls injector timing and pulse width. The ECM pulses the
fuel injectors based on information provided by its network of engine
sensors. The ECM uses the crankshaft position sensor to determine when to
pulse the injectors. Engine coolant temperature, intake air temperature,
air flow, and throttle position data are all used by the ECM to calculate
injector pulse width.
The ECM also uses its
network of sensors to determine whether all injectors should be pulsed at
the same time (simultaneous injection) or each injector should be pulsed
individually (sequential injection). Sequential injection is almost always
used during normal engine operation. Simultaneous injection may be used
when the engine is being cranked.
FAILURE
CONDITIONS
The ECM will set a
code and the MIL will turn on if an open circuit or short to ground is
detected in the fuel injector circuit during two driving
cycles.
|