Air conditioning System: Troubleshooting

DIAGNOSIS
GAUGE READINGS
OTHER SYMPTOMS
DIAGNOSIS
CORRECTION

•
Discharge air : slightly cool.
•
Thermostatic switch (with thermistor) : Low side gauge doesn't fluctuate with "ON" and "OFF".
Some air and moisture in system.
•
Check for leaks.
•
Discharge refrigerant from system.
•
Repair leaks as located.
•
Evacuate the system for at least 30 minutes.
•
Charge system with refrigerant.
•
Operate system and check performance.

•
Discharge air : Becomes warm all the time during hot part of day.
Some air and moisture in system.
•
Discharge refrigerant.
•
Evacuate system with a vacuum pump.
•
Recharge system to proper capacity.
•
Operate system and check performance.

•
Compressor : Cycles on and off too fast.
Defective thermostatic switch.
•
Replace thermostatic switch.
•
Operate system and check performance.

•
Compressor : Low side pressure builds too high before compressor turns on (cycle "ON" point too high).
Faulty thermostatic switch.
•
Replace the thermostatic switch.
•
Operate system and check performance.

•
Discharge air : Slightly cool.
System slightly low on refrigerant.
•
Check for leaks.
•
Discharge refrigerant.
•
Repair leaks.
•
Evacuate system using a vacuum pump.
•
Charge system with refrigerant.
•
Operate system and check performance.

•
Discharge air : Warm
•
System very low on refrigerant.
•
Possible leak in system.
•
Check for leaks.
•
Discharge refrigerant.
•
Evaporate system using a vacuum pump.
•
Charge system with refrigerant.
•
Operate system and check performance.

•
Discharge air : Slightly cool.
•
Expansion valve : Frost build up.
•
Expansion valve stuck.
•
Screen plugged.
•
Sensing bulb malfunction.
•
Discharge system.
•
Disconnect inlet line at expansion valve and remove and inspect screen.
•
Replace screen and reconnect inlet line.
•
Evacuate system using a vacuum pump.
•
Charge system with refrigerant.

•
Discharge air : Slightly cool.
•
High side pipe : Cool and also shows moisture or frost.
Restriction in high side of system
•
Discharge system.
•
Evacuate system using a vacuum pump.
•
Charge system with refrigerant.
•
Operate system and check performance.

•
Compressor : Noisy
Compressor malfunction
•
Disassemble compressor.
•
Inspect compressor.
•
Check compressor oil level.
•
Operate system and check performance.

•
Discharge air : Warm
•
High side pipe : Very hot
•
Faulty condenser.
•
Overcharged.
•
Check for loose or worn fan belt.
•
Inspect condenser for clogged air passage.
•
Check for refrigerant overcharge.
•
Operate system and check performance.

•
Discharge air : Slightly cool.
Large amount of air and moisture.
•
Discharge refrigerant from system.
•
Evacuate system using vacuum pump.
•
Charge system with refrigerant.
•
Operate system and check performance.

•
Discharge air : Warm
•
Evaporator : Moisture or frost.
Expansion valve stuck.
•
Discharge system.
•
Replace expansion valve.
•
Evacuate system using vacuum pump, then recharge system with refrigerant.
•
Operate system and check performance.