| 1. |
Disconnect the negative(-) battery
terminal. |
| 2. |
Remove the 2 screws and 2 bolts holding the
driver's crash pad lower panel.

|
| 3. |
Disconnect the hood release cable and the data
link connector from beneath the driver's crash pad lower
panel.

|
| 4. |
Remove the ETACS module from the bracket after
removing bolts.

|
| 5. |
Installation is the reverse of
removal. |
| 1. |
VEHICLE SPEED SENSING INTERMITTENT
WIPER

Time specification
T1 : Max. 0.5sec.
T2 : 0.6~0.7 sec. (Time of wiper motor 1
rotation)
T3 : At vehicle speed : 0km/h.
2.6±0.7 sec. (VR=0kΩ)~18.0±1sec.
(VR=50kΩ)
At vehicle speed = 100km/h or
more.
1.0±0.2sec. (VR=0kΩ)~10.0±1 sec.
(VR=50kΩ) |
| 2. |
WASHER

| A. |
Time specification
T1 : 0.3 sec.
T2 : 0.6~0.8 sec.
T3 : 0.2~0.6
sec. |
| B. |
Time specification
T1 : 0.3 sec.
T2 : 2.5~3.8 sec.
T3 : 0.6 sec. or
more |
| C. |
This function should be operated
preferentially even though the variable intermittent wiper is
operating. | |
| 3. |
DEFOGGER TIMER (Including Outside Mirror
Demister)
| (1) |
After ALT "L" ON, if the defogger is
switched ON, the defogger output is ON for 20 minutes
duration. |
| (2) |
If the defogger switch is pressed again,
or if the ignition is switched OFF during this time, the
defogger output is OFF. |

T1 : 20 ±
1min. |
| 4. |
SEAT BELT WARNING TIMER
| (1) |
Since the ignition is switched ON, the
seat belt warning indicator is illuminated infinitely (with
period : 0.6 sec., duty rate : 50%) and the chime bell is
sounded (with period : 0.9 sec., duty rate : 50%) for total
time 6 seconds. |
| (2) |
If the ignition is swithced off during
the indicator and the chime bell output, the indicator and the
chime bell are switched OFF.
If the seat belt is fastened during the
indicator and the chime bell output, the indicator and the
chime bell are switched OFF
immediately. |
| (3) |
When the ignition is already switched
ON, if the seat belt is not fastened, the chime bell is
sounded for 6 second and the warning indicator is illuminated
infinitely.

|
T1 : 6±1 sec., T2 : 0.45 ± 0.1 sec., T3 : 0.3
± 0.1 sec. |
| 5. |
DECAYED ROOM LAMP & KEYLESS UNLOCK
TIMER
| (1) |
When the first door (driver's or assist)
is opened, the room lamp shall brighten. When the last door is
closed, the room lamp will drop to 75% intensity, then fade
out over 5-6 seconds. |
| (2) |
If the door switch is ON for less than
0.1 sec., then no illumination
occurs. |
| (3) |
The fade resolution is over 32
steps. |
| (4) |
The room lamp must not flicker during
fade operation, if the ignition is switched
ON. |
| (5) |
With keyless UNLOCK, when the door is
closed, the room lamp is turned ON, then OFF after about 30
seconds. While the room lamp is ON due to keyless UNLOCK, if
another UNLOCK is received, the room lamp is again ON for 30
seconds.
While the room lamp is ON, If the door
is opened, the lamp is continued to ON. If the door is closed,
the lamp follows as the above step 1.
If keyless LOCK (ARM state) is received
during fade out, the room lamp is switched off
immediately.

T1 : 5.5 ± 0.5 sec., T2 : 30 ± 3
sec. | |
| 6. |
CENTRAL DOOR LOCK/UNLOCK
| (1) |
If transmitter(TX) lock or key lock
signal is received, all door lock output is
ON. |
| (2) |
With driver door lock state, if TX
unlock or key unlock signal is received, only driver door
unlock output is ON. |
| (3) |
Within 4 sec. since final unlock signal,
if TX unlock or key unlock signal is received again, all doors
unlock output is ON at driver door unlock state.
If the time (4 sec.) elapse, only driver
door unlock output is ON. |
| (4) |
Using safety knob, possible to central
door lock/unlock. |
| (5) |
Door key unlock switch is applied to
driver door, assist door and tailgate.

T1 : 0.5 ± 0.1 sec.
T2 : Max. 4 sec.
T3 : Min. 4
sec. | |
| 7. |
IGNITION KEY REMINDER

T1,T3 : 0.5 sec., T2 : 1 sec., T4 : Max.0.5
sec. |
| 8. |
POWER WINDOW TIMER
| (1) |
When the ignition is switched ON, the
power window relay output is turned
ON. |
| (2) |
When the ignition is switched OFF, the
power window output is maintained ON for 30 seconds and then
turned OFF. |
| (3) |
With the state of step 2, if the
driver's door or assist door is opened, the output shall be
turned OFF immediately.

T1 : 30 ± 3
sec. | |
| 9. |
DOOR OPEN WARNING
| (1) |
If the key is in the ignition key
cylinder and the driver's door is opened, the chime bell
sounds continually (period:0.9 sec. Duty
rate:50%). |
| (2) |
If the door is closed or the key is
removed, the chime stops immediately.

T1,T2 : 0.45 ± 0.1
sec. | |
| 10. |
TAIL LAMP AUTO CUT
| (1) |
When the tail lamp is switched ON, if
the ignition is switched OFF and the driver's door is opened,
the tail lamp should be automatically
OFF. |
| (2) |
With the ignition switched ON, if the
driver's door is opened and the ignition is switched OFF, the
tail lamp should be automatically
OFF. |
| (3) |
When the tail lamp is cut automatically,
if the tail lamp switch is turned OFF and ON, the tail lamp is
illuminated and auto cut function is cancelled.

| |
| 11. |
CRASH DOOR UNLOCK
| (1) |
With the ignition turned ON, if the air
bag is deployed, a crash signal is received and send an UNLOCK
output to all doors UNLOCK. |
| (2) |
After UNLOCK output, when LOCK is set,
UNLOCK pulse is output for 5 second period again.

T1 : 200 msec.
T2 : 40 msec.
T3 :
5±0.5sec. | |
| 12. |
TX LOCK TWO TIMES FUNCTION

T1 : 0.5 ± 0.1 sec.
T2 : 1 ± 0.2 sec.
T3 : 0.05 sec.
T4 : Max. 4 sec.
T5 : Min. 4
sec. |
| 13. |
PANIC ALARM
| (1) |
If panic switch is ON, horn output keeps
ON for 30 sec and if panic switch is ON again, horn output is
OFF. |
| (2) |
Panic mode is not affected at arm or
disarm state. |
| (3) |
While panic is operating, arm or disarm
function operates.

|
T1 : 30 ± 1
sec. |
| 1. |
ARM
FUNCTION
Pressing the remote key lock button will
result in a 0.5-second pulse issued to lock all doors.
Pressing the remote keypad unlock button once
will result in a 0.5-second unlock pulse issued to unlock all
doors.
As part of the arming sequence the alarm first
enters a pre-armed state before falling into the armed state. During
this pre-armed state alarm triggers are ignored. Pre-armed state can
be reached from the alarmed state, the start inhibit state or the
disarmed state. Pre-Arming of the alarm can be achieved by a press
of the lock button on the remote key.
In the pre-armed state the visible and audible
warnings are disabled.
This system enters the armed state if it is in
the pre-armed state and, after 0.6 sec, check actuator lock and each
door, hood and tail gate close, and no door warning switch (no key
in ignition).
On entering the arm state, a single flash of
the hazard lamps is given, period of cycle 2 second, duty rate
50%.
If TX lock signal is received when a door,
tail gate or hood is open, then lock output is given and a flash of
hazard is not given.
After the armed state is entered, if a lock
signal is received then a single flash of the hazard lamps is given,
period of cycle 2 second, duty rate 50%.
The armed state cannot be reached by locking
the car with the keys.

Time specification
T1 : 0.5 sec.
T2 : Max. 2 sec.
T3 : 1.0 ± 0.2
sec. |
| 2. |
DISARM
FUNCTION
Disarming can be performed while the alarm is
armed, or alarming, or after alarming. The alarm can be disarmed by
the following methods :
| A. |
Pressing the unlock button on the TX
key. The hazard lamps shall be flashed twice for 1sec period
(of cycle), 50% duty rate. |
| B. |
If door warning switch is on, IGN1 and
IGN2 are on in arm state, then arm state should be immediately
cancelled. This means that the driver is inside the vehicle
before pushing TX lock, so system should not
arm. |
In the disarm state the visible and audible
warnings are disabled and start is enabled.
In the disarm state, if TX key unlock command
is received, then the hazard lamps shall be flashed twice for period
of cycle 1 sec, 50% duty rate.
Disarm state cannot be reached using the door
locks by key.

Time specification
T1, T2 : 0.5 ± 0.1
sec. |
| 3. |
ALARM
FUNCTION
Once armed, should any door, hood or the
tailgate be opened, then.
| A. |
Start relay drive output is disabled, so
starting is inhibited |
| B. |
Audible (horn) and visual (hazard lamp)
warnings are issued, for three cycles, each cycle 27±2 sec.
duration on, 10±1 sec. off. The horn warning is continuously
occurring during the on period. The hazard lamps operate with
1 sec period, 50 % duty rate during the on
period |
| (1) |
The alarm is given in the case where a
door is opened with a key.
After this time, the system maintains
the start inhibit state, where no audible and visual warnings
are issued but engine starting is not possible.

Time specification
T1 : 27 ± 2 sec.
T2 : 10 ± 1sec.
T3 : 0.4~0.5
sec. | |
| 4. |
OPERATION DURING
ALARM CONDITIONS
| (1) |
Cancelling audible alarm with the remote
transmitter
CASE 1 : Door
closed
During or after alarming and then
closing all doors and a TX lock signal is received
Then
| A. |
The lock command is executed with
0.5 sec. ON |
| B. |
Horn and start inhibition are
OFF |
| C. |
Hazard lamp is flashed one time
(period : 2 sec., duty: 50%, within 2
sec.) |
| D. |
The state goes to arming mode
(after a lock state
check) |

Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2 sec.
CASE 2 : Door
Open
During or after alarming, with a door
open and a TX lock signal is received Then
| A. |
The lock command is executed with
0.5 sec. ON |
| B. |
Horn is disabled and start is
enabled after confirmation of actuator
lock |
At this time, when the door is
closed,
| A. |
Hazard lamp is flashed one time
(period : 2 sec., duty
50%) |
| B. |
The state goes to arming
mode |

Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2
sec. |
| (2) |
New alarm conditions
Second alarm condition during
alarming.
When another alarm occurs during
alarming, the starting is disabled, and the alarm continues to
sound for the remained time of warning signal. The alarm
continues to sound after the second alarm condition is
removed.
New alarm condition occurs after
alarming (with all entrances closed)
If any entrance is opened again
then
| A. |
The horn is ON 3
times |
| C. |
Hazard lamps flash during the ON
time of horn |
New alarm condition occur after alarming
(with any entrance open).
If another entrance is opened, the ETACS
module keeps start disabled and there is no horn
output.

|
| (3) |
Key operation during alarm
After the alarm state or start inhibit
state are entered, if door warning switch on (key in ignition)
&IGN 2 ON, if IGN 2 state is changed to OFF within 30sec,
remain in alarm state. |
| (4) |
Disarming using the key
During alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled, and the
system enters the disarm state.
After alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled, and the
system enters the disarm state.

| |
| 5. |
ALARM STATE IN POWER
DOWN
If the battery is disconnected to the ETACS
module in the following states:
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restarted (timer reset to
0).
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restart (timer reset to
0).

| |