| 1. |
Disconnect the negative (-)
terminal.

|
| 2. |
Disconnect the generator connector and remove
the "B+" terminal cable.

|
| 3. |
Loosen the belt tension adjusting bolt and
remove the mounting bolt.

|
| 4. |
Remove the belt by pushing the generator
inward.

|
| 5. |
Remove the generator assembly.

|
| 6. |
Installation is the reverse of
removal.
| 1. |
Position the generator and insert
the support bolt. (Do not attach the
nut) |
| 2. |
Push the generator forward and
determine how many spacers (thickness : 0.198 mm) should
be inserted between the front leg of the generator and
the front case. (space "A" in the
illustration)
(There should be enough spacers so
that they do not fall out when you let go of
them.) |
| 3. |
Insert the spacers (space "A" in
the illustration), attach the nut, and complete the
installation.

| | |
BRUSH

| 1. |
Unsolder the pigtail and remove the old brush
and spring. |
| 2. |
Install the brush spring and a new brush in
the brush holder. |
| 3. |
Insert the brush so that there is a space of 2
to 3 mm (0.079 to 0.118 in.) between the limit line and the end of
the brush holder. |
| 4. |
Solder the pigtail to the brush
holder. |
| 1. |
Remove the generator cover using a screw
driver.

|
| 2. |
Loosen the mounting bolts and disconnect the
brush holder assembly.

|
| 3. |
Remove the slip ring guide.

|
| 4. |
Remove the nut, pully and spacer.

|
| 5. |
Loosen the 4 through bolts.

|
| 6. |
Disconnect the rotor and cover.

|
| 7. |
Reassembly is the reverse of
disassembly. |
ROTOR
| 1. |
Check the rotor coil for continuity. Check to
make sure that there is continuity between the slip rings. If
resistance is extremely low, it means that there is a short. If
there is no continuity or if there is a short circuit, replace the
rotor assembly.

|
| 2. |
Check the rotor coil for ground. Check to make
sure that there is no continuity between the slip ring and the
core.
If there is continuity, replace the rotor
assembly.

|
STATOR
| 1. |
Make a continuity check on the stator coil.
Check to make sure that there is continuity between the coil
leads.
If there is no continuity, replace the stator
assembly.

|
| 2. |
Check the coil for grounding. Check to make
sure that there is no continuity between the coil and the
core.
If there is continuity, replace the stator
assembly.

| |