Home
›
Body Electrical System
›
Lighting System
›
Hazard Lamp Switch
Lighting System › Hazard Lamp Switch: Repair procedures
INSPECTION
1.
Disconnect the negative(-) battery terminal.
2.
Remove the center facia panel with a flat-tip screwdriver, then disconnect the switch connector.
3.
Operate the switch and check for continuity between terminals with an ohmmeter.