Home › Restraint › General Information

General Information: General Information

GENERAL
INFLATOR MODULE (DAB, PAB, SAB)

1.
When removing the airbag module or handling a new airbag module, it should be placed with the pad top surface facing up. In this case, the twin-lock type connector lock lever should be in the locked state and care should be taken to place it so the connecter will not be damaged. Do not store a steering wheel pad on top of another one. (Storing the pad with its metallic surface up may lead to a serious accident if the airbag should inflate accidentally.)
2.
Never measure the resistance of the airbag squib. (This may cause the airbag to deploy, which is very dangerous.)
3.
Store the airbag module where the ambient temperature remains below 93°C (200°F), without high humidity and away from electrical noise.
4.
During electric welding, disconnect the airbag under the steering column near the MULTI-FUNCTION SWITCH connector before starting work.
DUAL STAGE AIRBAGS (DAB, PAB)
In a light crash, the first stage of the duel stage airbag is deployed, and the second stage is deployed in 127ms after deployment of the first stage by SRSCM.
When scrapping a car of intentionally deploying the replaced airbag modules, deploy individual stage.
CUSTOMER CAUTIONS
1.
Be sure to proceed with airbag related service only after approx. 30 seconds or longer from the time the ignition switch is turned to the LOCK position and the negative (-) battery cable is disconnected from the battery. The airbag system is equipped with a back-up power source to assure the deployment of airbags when the battery cable is disconneted during an accident. The back-up power is available for approx. 150ms.
2.
When the negative (-) battery cable is disconnected from the battery, the clock and audio system's memory will be wiped out. So before starting work, make a record of the contents of the audio system's memory. When the work is finished, reset the audio system and adjust the clock.
3.
Symptoms of malfunction of the airbag system are difficult to detect, so the diagnostic codes become the most important source of information when troubleshooting.
4.
When troubleshooting the airbag system, always inspect the diagnostic codes before disconnecting the battery.
5.
Never use airbag parts from another vehicle. When replacing parts, replace them with new parts.
6.
Never attempt to disassemble and repair the airbag modules (DAB, PAB, SAB, BPT), clock spring and wiring in order to reuse them.
7.
If any component of the SRS has been dropped, or if there are cracks, dents or other defects in the case, bracket or connector, replace them with new ones.
8.
After work on the airbag system is completed, perform an SRS SRI check. The airbag indicator lamp can be triggered by faults in other circuit in some cases. Therefore if the airbag indicator lamp goes on, be sure to erase the DTC codes using the Hi-Scan Pro just after repairing or replacing the troubled parts, including the fuse.
9.
Especially when performing body welding, never fail to disconnect the battery's negative (-) terminal.