| CIRCUIT INSPECTION
(SRE-LC) |
DTC
|
B2500 Warning
lamp failure
|
INSPECTION PROCEDURE
| 1. |
Check the fuse.
| A. |
Remove fuse airbag fuse and airbag
warning lamp fuse from the junction
block. |
| B. |
Inspect the state of the
fuses. |
|
| 2. |
Check the SRS warning lamp
circuit.
| A. |
Connect the negative (-) terminal cable
to the battery. |
| B. |
Turn the ignition switch to
ON. |
| A. |
Measure voltage at the harness side
connector of the SRSCM.
Voltage: 9-16
V

|
| B. |
Check the SRS SRI (Service Reminder
Indicator).
OK: SRS SRI
ON |

|
CIRCUIT INSPECTION (DUAL STAGE AIRBAG)
DTC
|
B2500 Warning
lamp failure
|
INSPECTION PROCEDURE
| 1. |
Check the fuse.
| A. |
Remove fuse airbag fuse and airbag
warning lamp fuse from the junction
block. |
| B. |
Inspect the state of the
fuses. |
|
| 2. |
Check the SRS warning lamp
circuit.
| A. |
Connect the negative (-) terminal cable
to the battery. |
| B. |
Turn the ignition switch to
ON. |
| A. |
Measure voltage at the harness side
connector of the SRSCM.
Voltage :
10-16.5 V

|
| B. |
Check the SRS SRI (Service Reminder
Indicator).
OK : SRS SRI
ON

| |