DESCRIPTION
The Idle Speed Control
(ISC) actuator has two coils that are driven by separate ECM driver
stages. Depending on the pulse duty factor, the equilibrium of the
magnetic forces of the two coils will result in different directions for
the magnetic forces of the two coils which will result in different
positions for the actuator. In parallel to the throttle valve, a bypass
hose line is arranged where the ISC actuator is inserted.
FAILURE CONDITION
The ECM will set a code
and the MIL will turn on if ISC actuator's opening coil driver stage [for
P1506] or closing coil driver stage [for P1508] is shorted to battery
voltage during two driving cycles.
CIRCUIT DIAGRAM
TEST PROCEDURE
|