BURGLAR
ALARM SYSTEM
| •
|
A door is unlocked without using the
transmitter. |
| •
|
The trunk lid is opened without using the
key. |
| •
|
The engine starter circuit and battery
circuit are bypassed by breaking the ignition
switch. |
KEYLESS
ENTRY SYSTEM
| 1. |
ARM
FUNCTION
Pressing the remote key lock button will
result in a 0.5-second pulse issued to lock all doors.
Pressing the remote keypad unlock button
once will result in a 0.5-second unlock pulse issued to unlock all
doors.
As part of the arming sequence the alarm
first enters a pre-armed state before falling into the armed state.
During this pre-armed state alarm triggers are ignored. Pre-armed
state can be reached from the alarmed state, the start inhibit state
or the disarmed state. Pre-Arming of the alarm can be achieved by a
press of the lock button on the remote key.
In the pre-armed state the visible and
audible warnings are disabled.
This system enters the armed state if it is
in the pre-armed state and, after 0.6 sec, check actuator lock and
each door, hood and tail gate close, and no door warning switch (no
key in ignition).
On entering the arm state, a single flash of
the hazard lamps is given, period of cycle 2 second, duty rate
50%.
If TX lock signal is received when a door,
tail gate or hood is open, then lock output is given and a flash of
hazard is not given.
After the armed state is entered, if a lock
signal is received then a single flash of the hazard lamps is given,
period of cycle 2 second, duty rate 50%.
The armed state cannot be reached by locking
the car with the keys.

Time specification
T1 : 0.5 sec.
T2 : Max. 2 sec.
T3 : 1.0 ± 0.2
sec. |
| 2. |
DISARM
FUNCTION
Disarming can be performed while the alarm
is armed, or alarming, or after alarming. The alarm can be disarmed
by the following methods :
| A. |
Pressing the unlock button on the TX
key. The hazard lamps shall be flashed twice for 1sec period
(of cycle), 50% duty rate. |
| B. |
If door warning switch is on, IGN1 and
IGN2 are on in arm state, then arm state should be immediately
cancelled. This means that the driver is inside the vehicle
before pushing TX lock, so system should not
arm. |
In the disarm state the visible and audible
warnings are disabled and start is enabled.
In the disarm state, if TX key unlock
command is received, then the hazard lamps shall be flashed twice
for period of cycle 1 sec, 50% duty rate.
Disarm state cannot be reached using the
door locks by key.

Time specification
T1, T2 : 0.5 ± 0.1
sec. |
| 3. |
ALARM
FUNCTION
Once armed, should any door, hood or the
tailgate be opened, then.
| A. |
Start relay drive output is disabled,
so starting is inhibited |
| B. |
Audible (horn) and visual (hazard
lamp) warnings are issued, for three cycles, each cycle 27±2
sec. duration on, 10±1 sec. off. The horn warning is
continuously occurring during the on period. The hazard lamps
operate with 1 sec period, 50 % duty rate during the on
period |
The alarm is given in the case where a door
is opened with a key.
After this time, the system maintains the
start inhibit state, where no audible and visual warnings are issued
but engine starting is not possible.

Time specification
T1 : 27 ± 2 sec.
T2 : 10 ± 1sec.
T3 : 0.4~0.5
sec. |
| 4. |
OPERATION DURING
ALARM CONDITIONS
| (1) |
Cancelling audible alarm with the
remote transmitter.
CASE 1 :
Door closed
During or after alarming and then
closing all doors and a TX lock signal is received
Then
| A. |
The lock command is executed
with 0.5 sec. ON |
| B. |
Horn and start inhibition are
OFF |
| C. |
Hazard lamp is flashed one time
(period : 2 sec., duty: 50%, within 2
sec.) |
| D. |
The state goes to arming mode
(after a lock state
check) |
| E. |
The start is
enabled

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2 sec.
CASE 2 :
Door Open
During or after alarming, with a door
open and a TX lock signal is received Then
| A. |
The lock command is executed
with 0.5 sec. ON |
| B. |
Horn is disabled and start is
enabled after confirmation of actuator
lock |
At this time, when the door is
closed,
| A. |
Hazard lamp is flashed one time
(period : 2 sec., duty
50%) |
| B. |
The state goes to arming
mode

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2
sec. |
| (2) |
New alarm conditions
Second alarm condition during
alarming.
When another alarm occurs during
alarming, the starting is disabled, and the alarm continues to
sound for the remained time of warning signal. The alarm
continues to sound after the second alarm condition is
removed.
New alarm condition occurs after
alarming (with all entrances closed)
If any entrance is opened again
then
| A. |
The horn is ON 3
times |
| C. |
Hazard lamps flash during the ON
time of horn |
New alarm condition occur after
alarming (with any entrance open).
If another entrance is opened, the
ETACS module keeps start disabled and there is no horn
output.

|
| (3) |
Key operation during
alarm
After the alarm state or start inhibit
state are entered, if door warning switch on (key in ignition)
&IGN 2 ON, if IGN 2 state is changed to OFF within 30sec,
remain in alarm state. |
| (4) |
Disarming using the key
During alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled, and the
system enters the disarm state.
After alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled, and the
system enters the disarm state.

| |
| 5. |
ALARM STATE IN
POWER DOWN
If the battery is disconnected to the ETACS
module in the following states :
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restarted (timer reset to
0).
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restart (timer reset to
0).

|
| 6. |
ALARM HOLD
MODE
| (1) |
In case of opening the trunk by trunk
unlock switch during arm state, the alarming is
hold.
When received transmitter (TX) trunk
signal in arm state, trunk open by output trunk lid open relay
signal for 500ms and then holding alarm.
But the door and hood except trunk is
still in the arm state. |
| (2) |
Trunk is going to the arm state just
case trunk is still closed for 2 sec.

T1 : Max. 0.2 sec., T2 : 2
sec. | | |