Item
|
Detecting
Condition
|
Possible
cause
|
Monitoring
Strategy
|
● Circuit
continuity check (Change-over valve)
|
●
Open in control circuit ● Faulty
DMTL ● Faulty PCM
|
Threshold
value
|
●
Disconnected
|
Enable
Conditions
|
● Open
circuit
|
Diagnostic
Time
|
●
Continuous
|
Fail
Safe
|
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Evap. Leakage Test
Evaporative Emissions Systems (EVAP) Leak
Tests can be run by the Scan Tool. The tests are automated and
provide either a pass-fail result or directions to check for
DTCs.

| (1) |
Connect scantool to Data Link
Connector(DLC). |
| (2) |
Warm up the engine to normal operating
temperature. |
| (3) |
Perform "07 EVAP. LEAKAGE TEST"
mode |
| (4) |
Is DTC P2418 set again?

▶ Go to "W/Harness Inspection"
procedure.

▶ Fault is intermittent caused by poor
contact in the sensor’s and/or PCM’s connector or was repaired
and PCM memory was not cleared. Thoroughly check connectors
for looseness, poor connection,bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and go to "Verification vehicle Repair"
procedure | |
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination,deterioration, or
damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of vehicle Repair" procedure.

▶ Go to "Power circuit insepction"
procedure. |
| 2. |
Disconnect DM-TL
connector. |
| 3. |
Ignition "ON" & Engine
"OFF" |
| 4. |
Measure voltage between terminal 4 of DM-TL
harness connector and chassis ground.

|
| 5. |
Is measure voltage within
Specification?

▶ Go to "Control circuit insepction"
procedure.

▶ Short circuit to chassis ground between
DM-TL harness connector and control relay.
▶ Open circuit between DM-TL harness connector
and control relay.
▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.
| 1. |
In case,when DM-TL connector is
disconnected, the voltage of DM-TL terminal 4 is
0V.
▶ Possible cause: Open or short
circuit in battery power line after fuse (10A ECU
#1). |
| 2. |
PCM also sets P0444 and P0562 if
it detects the open circuit in DM-TL power
line. | | |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
Check for open in harness
| (2) |
Disconnect DM-TL
connector. |
| (3) |
Ignition "ON" & Engine
"OFF" |
| (4) |
Measure voltage between terminal 2 of
DM-TL harness connector and chassis ground.

|
| (5) |
Is measure voltage within
Specification?

▶ Go to "Component Inspection"
procedure.

▶ Short circuit to chassis ground
between DM-TL harness connector and ECM harness
connector
▶ Open circuit between DM-TL harness
connector and PCM harness connector
▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.
|
In case,when the DM-TL connector
is disconnected,the voltage of DM-TL terminal 1 is 0
V.
▶ Possible cause: Open or short
between terminal 25 of PCM and terminal 2 of
DM-TL. | | |
| 1. |
Check for short between Solenoid Control and
battery
| (2) |
Disconnect Fuel sender
connector. |
| (3) |
Measure resistance between terminal 2
and 4 of Fuel sender harness connector.(To sender
side)

|
| (4) |
Is measure resistance within
Specification?

▶ Substitute with a known-good PCM and
check for proper operation. If the problem is corrected
replace PCM and then go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known-good Pump
motor and check for proper operation. If the problem is
corrected, replace Pump motor and then go to "Verification of
Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code (DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs. |
| 3. |
Operate the vehicle within conditions noted in
the freeze frame data or enable
conditions. |
| 4. |
Monitor that all rediness test have been
verified as "Complete" |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |

|