Item
|
Detecting
Condition
|
Possible
cause
|
Monitoring
Strategy
|
● Circuit
continuity check (Pump motor)
|
●
Open in control circuit ● Short to ground
in control circuit. ● Faulty
DMTL. ● Faulty PCM
|
Threshold
value
|
● Shorted to
GND
|
Enable
Conditions
|
● Open
circuit
|
Diagnostic
Time
|
●
Continuous
|
Fail
Safe
|
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Evap. Leakage Test
Evaporative Emissions Systems (EVAP) Leak
Tests can be run by the Scan Tool. The tests are automated and
provide either a pass-fail result or directions to check for
DTCs.

| (1) |
Connect scantool to Data Link
Connector(DLC). |
| (2) |
Warm up the engine to normal operating
temperature. |
| (3) |
Perform "07 EVAP. LEAKAGE TEST"
mode |
| (4) |
Is DTC P2401 set again?

▶ Go to "W/Harness Inspection"
procedure.

▶ Fault is intermittent caused by poor
contact in the sensor’s and/or PCM’s connector or was repaired
and PCM memory was not cleared. Thoroughly check connectors
for looseness, poor connection,bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and go to "Verification vehicle Repair"
procedure | |
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination,deterioration, or
damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of vehicle Repair" procedure.

▶ Go to "Control circuit insepction"
procedure. |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
Check for short to ground in
harness
| (2) |
Disconnect DM-TL connector and PCM
connector. |
| (3) |
Ignition "ON" & Engine
"OFF" |
| (4) |
Measure resistance between terminal 1 of
DM-TL harness connector and chassis ground..

|
| (5) |
Is measure resistance within
Specification?

▶ Go to "Check for short between Pump
Control and Solenoid Control harness " as below.

▶ Short circuit to chassis ground
between DM-TL harness connector and PCM harness
connector.
▶ Repair as necessary and then go to
"Verification of Vehicle Repair"
procedure. | |
| 2. |
Check for short between Pump Control and
Solenoid Control harness
| (2) |
Disconnect DM-TL connector and PCM
connector. |
| (3) |
Ignition "ON" & Engine
"OFF" |
| (4) |
Measure resistance between terminal 1
and 2 of DM-TL harness connector.

|
| (5) |
Is measure resistance within
Specification?

▶ Go to "Component Inspection"
procedure.

▶ Shorted circuit between Pump Control
circuit and Solenoid Control circuit.
▶ Repair as necessary and then go to
"Verification of Vehicle Repair"
procedure. | |
| 1. |
Check for short between Pump Control and
chassis ground.
| (2) |
Disconnect DM-TL
connector. |
| (3) |
Measure resistance between terminal 1 of
DM-TL harness connector and chassis ground.(To DM-TL
side)

|
| (4) |
Is measure resistance within
Specification?

▶ Substitute with a known-good PCM and
check for proper operation. If the problem is corrected,
replace PCM and then go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known-good Pump
motor and check for proper operation. If the problem is
corrected, replace Pump motor and then go to "Verification of
Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code (DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs. |
| 3. |
Operate the vehicle within conditions noted in
the freeze frame data or enable
conditions. |
| 4. |
Monitor that all rediness test have been
verified as "Complete" |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |

|