POWER
RELAY TEST (TYPE A)
| 1. |
There should be continuity between the No.3
and No.4 terminals when power and ground are connected to the No.1
and No.2 terminals. |
| 2. |
There should be no continuity between the
No.3 and No.4 terminals when power is disconnected.


|
POWER
RELAY TEST (TYPE B)
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.4
and No.3 terminals. |
| 2. |
There should be no continuity between the
No.1 and No.2 terminals when power is disconnected.

|

POWER
RELAY TEST (TYPE C)
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.3
and No.5 terminals. |
| 2. |
There should be continuity between the No.1
and No.4 terminals when power is disconnected.


|