| 1. |
Drain the coolant so its level is below
thermostat. |
| 2. |
Remove the inlet fitting and
gasket.

|
| 3. |
Remove the
thermostat. |
| 4. |
Immerse thermostat in hot coolant to check
proper valve opening temperature. Replace if necessary.
Valve opening temperature : 82°C
(177°C)
Full opening temperature : 95°C (205
°F)
|

|
COOLANT
TEMPERATURE SENSOR
| 1. |
Heat the sensor by submerging it in hot
engine coolant. |
| 2. |
Check that the resistance is within the
specified range.
Resistance
At : 20°C (68°F) : 2.31 ~ 2.59
kΩ
| |
| 1. |
Check that the flange of the thermostat is
correctly seated in the socket of the thermostat
housing. |
| 2. |
Install a new gasket and the coolant inlet
fitting. |
| 3. |
Refill the system with clean
coolant.
Tightening
torque
Coolant temperature sensor
:
20 ~ 40 Nm (200 ~ 400 kg.cm, 15 ~ 30
lb.ft)
| |