Item
|
Detecting Condition
|
Possible cause
|
Monitoring Strategy
|
● DM-TL : pump motor current
|
● Leakage on EVAP.
SYSTEM ● Faulty DMTL. ● Faulty PCM
|
Threshold value
|
● Current at reference mode phase > 40
mA
|
Enable Conditions
|
|
Diagnostic Time
|
● 10 sec
|
Fail Safe
|
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Evap. Leakage Test
Evaporative Emissions Systems (EVAP) Leak
Tests can be run by the Scan Tool. The tests are automated and
provide either a pass-fail result or directions to check for
DTCs.

| (1) |
Connect scantool to Data Link
Connector(DLC). |
| (2) |
Warm up the engine to normal operating
temperature. |
| (3) |
Perform "07 EVAP. LEAKAGE TEST"
mode |
| (4) |
Is DTC P2406 set again?

▶ Go to "W/Harness Inspection"
procedure.

▶ Fault is intermittent caused by poor
contact in the sensor’s and/or PCM’s connector or was repaired
and PCM memory was not cleared. Thoroughly check connectors
for looseness, poor connection,bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and go to "Verification vehicle Repair"
procedure | |
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination,deterioration, or
damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to
"Verification of vehicle Repair" procedure.

▶ Go to "Power circuit insepction"
procedure. |
| 2. |
Disconnect DM-TL
connector. |
| 3. |
Ignition "ON" & Engine
"OFF" |
| 4. |
Measure voltage between terminal 4 of DM-TL
harness connector and chassis ground.

|
| 5. |
Is measure voltage within
Specification?

▶ Go to "Control circuit insepction"
procedure.

▶ Check for open or short circuit between
Main relay and terminal 3 of DM-TL
▶ Especially check "10A ECU" fuse is blown
or not installed Repair as necessary and go to "Verification Vehicle
Repair" procedure. |
| CONTROL CIRCUIT
INSPECTION |
| 2. |
Disconnect DM-TL
connector. |
| 3. |
Ignition "ON" & Engine
"OFF" |
| 4. |
Measure voltage between terminal 2 of DM-TL
harness connector and chassis ground.

|
| 5. |
Is measure voltage within
Specification?

▶ Go to "Component Inspection"
procedure.

▶ Check for Open or short in Solenoid
Control harness.
▶ Repair as necessary and then go to
"Verification of Vehicle Repair"
procedure. |
| 1. |
Check Solenoid
| (2) |
Disconnect DM-TL
connector. |
| (3) |
Measure resistance between terminal 2
and 4 of DM-TL harness connector.(To sender side)

|
| (4) |
Is measure resistance within
Specification?

▶ Go to "Check Pump" as
below.

▶ Substitute with a known-good DM-TL
and check for proper operation. If the problem is corrected,
replace DM-TL and then go to "Verification of Vehicle Repair"
procedure.. | |
| 2. |
Check Pump
| (2) |
Disconnect DM-TL
connector. |
| (3) |
Measure resistance between terminal 1
and 4 of DM-TL harness connector.(To sender side)

|
| (4) |
Is measure resistance within
Specification?

▶ Substitute with a known-good PCM and
check for proper operation. If the problem is corrected,
replace PCM and then go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known-good DM-TL
and check for proper operation. If the problem is corrected,
replace DM-TL and then go to "Verification of Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code (DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs. |
| 3. |
Operate the vehicle within conditions noted
in the freeze frame data or enable
conditions. |
| 4. |
Monitor that all rediness test have been
verified as "Complete" |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |

|