Home › Fuel System › Troubleshooting

P1624

COMPONENT LOCATION

GENERAL DESCTIPTION
DTC DESCRIPTION
DTC DETECTING CONDITION
Item
Detecting Condition
Possible cause
Monitoring Strategy
● Circuit continuity check
● Open in battery and control circuit
● Short to ground in control circuit (pin 50 to GND)
● Faulty FAN Relay
● Faulty PCM
Threshold value
● Short to GND or disconnected
Enable Conditions
● Cooling fan control enabled
Diagnostic Time

Fail Safe

MONITOR DTC STATUS
1.
Connect scantool to Data Link Connector(DLC).
2.
Warm up the engine to normal operating temperature.
3.
Monitor the "COOLING FAN" parameter on the scantool.

The data shown above is only for reference and there may be a little difference actually.
Service standard
4.
Is parameter displayed within specifications?

▶ Fault is intermittent caused by poor contact in the sensor’s and/or PCM’s connector or was repaired and PCM memory was not cleared.Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination,deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to "W/Harness Inspection" procedure
TERMINAL & CONNECTOR INSPECTION
1.
Many malfunctions in the electrical system are caused by poor harness and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination,deterioration, or damage.
3.
Has a problem been found?

▶ Repair as necessary and go to "Verification of vehicle Repair" procedure.

▶ Go to "Power circuit inspection" procedure.
POWER CIRCUIT INSPECTION
1.
Check for open in harness
(1)
Ignition "OFF"
(2)
Disconnect RAD FAN Relay.
(3)
Ignition "ON" & Engine "OFF"
(4)
Measure voltage between terminal 1 and 5 of RAD FAN Relay harness connector and chassis ground.

(5)
Is measure voltage within Specification?

▶ Go to "Control circuit insepction" procedure.

▶ Open circuit or short circuit to chassis ground between RAD FAN Relay harness connector and ECU #1 Fuse 10A.
▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure.
CONTROL CIRCUIT INSPECTION
1.
Check for short to ground in harness
(1)
Ignition "OFF"
(2)
Disconnect RAD FAN Relay.
(3)
Ignition "ON" & Engine "OFF"
(4)
Measure voltage between terminal 3 of RAD FAN Relay harness connector and chassis ground.

(5)
Is measure voltage within Specification?

▶ Go to "Component Inspection" procedure.

▶ Check for open or Short to ground in control circuit.
▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure.
In case,when RAD FAN Relay connector is disconnected,the voltage at terminal 3 is 0V.
▶ Possible cause : Short to ground in control circuit
COMPONENT INSPECTION
1.
Check RAD FAN Relay
(1)
Ignition "OFF"
(2)
Disconnect RAD FAN Relay.
(3)
Measure resistance between terminal 3 and 5 of RAD FAN Relay connector(To sensor side)

(4)
Is measure resistance within Specification?

▶ Substitute with a known-good PCM and check for proper operation. If the problem is corrected, replace PCM and then go to "Verification of Vehicle Repair" procedure.

▶ Substitute with a known-good RAD FAN Relay heater and check for proper operation. If the problem is corrected, replace RAD FAN Relay and then go to "Verification of Vehicle Repair" procedure.
VERIFICATION OF VEHICLE REPAIR
1.
Monitor and record the Freeze Frame Data for the Diagnostic Trouble Code (DTC) which has been diagnosed.
2.
Using a Scantool, Clear the DTCs.
3.
Operate the vehicle within conditions noted in the freeze frame data or enable conditions.
4.
Monitor that all rediness test have been verified as "Complete"
5.
Are any DTCs present ?

▶ Go to the applicable troubleshooting procedure.

▶ System is performing to specification at this time.