Item
|
Detecting Condition
|
Possible cause
|
Monitoring Strategy
|
● Circuit continuity check
|
● Short to battery in control
circuit ● Faulty FAN
Relay ● Faulty PCM
|
Threshold value
|
● Short to battery
|
Enable Conditions
|
● Cooling fan control enabled
|
Diagnostic Time
|
● Continuous
|
Fail Safe
|
● Heater open loop
control
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 2. |
Warm up the engine to normal operating
temperature. |
| 3. |
Monitor the "COOLING FAN" parameter on the
scantool.

Service
standard |
| 4. |
Is parameter displayed within
specifications?

▶ Fault is intermittent caused by poor
contact in the sensor’s and/or PCM’s connector or was repaired and
PCM memory was not cleared.Thoroughly check connectors for
looseness, poor connection, bending, corrosion,
contamination,deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure.

▶ Go to "W/Harness Inspection"
procedure |
| TERMINAL & CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination,deterioration, or
damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to
"Verification of vehicle Repair" procedure.

▶ Go to "Control circuit inspection"
procedure. |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
Check for short to ground in
harness
| (2) |
Disconnect RAD FAN
Relay. |
| (3) |
Ignition "ON" & Engine
"OFF" |
| (4) |
Measure voltage between terminal 3 of
RAD FAN Relay harness connector and chassis
ground.

|
| (5) |
Is measure voltage within
Specification?

▶ Go to "Component Inspection"
procedure.

▶ Check for open or Short to ground in
control circuit.
▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.
|
In case,when RAD FAN Relay
connector is disconnected,the voltage at terminal 3 is
0V.
▶ Possible cause : Short to
ground in control
circuit | | |
| 1. |
Check RAD FAN Relay
| (2) |
Disconnect RAD FAN
Relay. |
| (3) |
Measure resistance between terminal 3
and 5 of RAD FAN Relay connector(To sensor side)

|
| (4) |
Is measure resistance within
Specification?

▶ Substitute with a known-good PCM and
check for proper operation. If the problem is corrected,
replace PCM and then go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known-good RAD FAN
Relay heater and check for proper operation. If the problem
is corrected, replace RAD FAN Relay and then go to
"Verification of Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
| 1. |
Monitor and record the Freeze Frame Data for
the Diagnostic Trouble Code (DTC) which has been
diagnosed. |
| 2. |
Using a Scantool, Clear the
DTCs. |
| 3. |
Operate the vehicle within conditions noted
in the freeze frame data or enable
conditions. |
| 4. |
Monitor that all rediness test have been
verified as "Complete" |
| 5. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |

|