Home › Heating,Ventilation, Air Conditioning › Blower › Blower Unit

Blower › Blower Unit: Repair procedures

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crush pad.(Refer to BD group)
3.
Disconnect the connectors from the intake actuator, the blower motor and power mosfet.
4.
Remove the cowl cross bar assembly.(Refer to BD group)
5.
Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

Make sure that there is no air leaking out of the blower and duct joints.
6.
Installation is the reverse order of removal.