The charging system
includes a battery, generator with a built-in regulator, and the charging
indicator light and wiring.
The generator has
eight built-in diodes, each rectifying AC current to DC
current.
Therefore, DC current
appears at generator "B" terminal.
In addition, the
charging voltage of this generator is regulated by the battery voltage
detection system.
The generator is
regulated by the battery voltage detection system. The main components of
the generator are the rotor, stator, rectifier, capacitor brushes,
bearings and V-ribbed belt pulley. The brush holder contains a built-in
electronic voltage regulator.
|