| 1. |
Remove the valve pad (A) and disconnect the
vacuum hose (B).

|
| 1. |
Install the PCV valve according to the
reverse order of the "REMOVAL" procedure.
PCV Valve Installation : 7.8 ~ 11.8
N·m (0.8 ~ 1.2 kgf·m, 5.8 ~ 8.7 lbf·ft)
| |
| 2. |
Insert a thin stick(A) into the PCV valve(B)
from the threaded side to check that the plunger
moves. |
| 3. |
If the plunger does not move, the PCV valve
is clogged. Clean it or replace.

| |