Due to the increasing
ambient temperature, fuel vapors are generated in the tank. In order to
control the release of these vapors to the atmosphere, the evaporative
emissions control system is used. The evaporative emission control system
reduces hydrocarbon (HC) emissions by trapping fuel tank vapors until they
can be burned in the combustion process. Evaporating fuel is stored in a
charcoal canister until it can be flushed into the intake manifold. The
evaporative emission control system is made up of a fuel tank that can be
completely sealed from outside air, a Fuel Tank Pressure Sensor (FTPS), a
Canister Close Valve (CCV) that seals the canister from the outside air, a
canister filled with activated charcoal granules, a Purge Control Solenoid
Valve (PCSV). The evaporative emission system can be checked for leaks by
sealing the system off from the outside air, creating a vacuum, and
monitoring if the system can hold that vacuum sufficiently for a set
amount of time. If it cannot, a leak exists somewhere in the
system.
When ECM/PCM detects
Open or Short in circuit, ECM/PCM sets DTC P0624.
Item
|
Detecting
Condition
|
Possible
Cause
|
DTC Strategy
|
| •
|
Circuit continuity check (high, low,
or open) | |
|
Enable Conditions
|
|
Threshold Value
|
| •
|
Short circuit to
battery |
| •
|
Short circuit to
ground |
|
Diagnostic Time
|
|
MIL ONCondition
|
|


| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to
"Verification of vehicle Repair" procedure.

▶ Go to "Main relay circuit inspection"
procedure. |
| 2. |
Disconnect the instrument cluster harness
connector. |
| 3. |
Measure the voltage between terminal
11/M09-1 of harness connector and ground.

|
| 4. |
Is the measured voltage within specification
?

▶ Go to "Control circuit inspection"
procedure.

▶ Check the fuse(ECU A 30A) between battery
and cluster.
▶ Repair Open or Short in power circuit and
then go to "Verification of vehicle Repair"
procedure. |
| CONTROL CIRCUIT
INSPECTION |
| 2. |
Disconnect ECM/PCM harness
connector. |
| 4. |
Measure the voltage between terminal
53/C01-1 (94/C01) of PCM(ECM) harness connectorand
ground.
PCM A/T

ECM M/T

|
| 5. |
Is the measured voltage within specification
?

▶ Go to "Component inspection"
procedure.

▶ Check the bulb and repair as
necessary.
▶ Repair Open or Short in control circuit
and then go to "Verification of vehicle Repair"
procedure. |
| 2. |
Disconnect ECM/PCM harness
connector. |
| 3. |
Short terminal 53/C01-1 (94/C01) of PCM(ECM)
harness connector to ground.
Specification : Fuel filler cap lamp
ON
|
PCM A/T

ECM M/T

|
| 4. |
Is the Fuel filler cap warning lamp turned
on normally?

▶ Substitute with a known - good ECM/PCM and
check for proper operation. If the problem is corrected, replace
ECM/PCM and go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known - good instrument
cluster and check for proper operation. If the problemis corrected,
replace instrument cluster and go to "Verification of Vehicle
Repair" procedure. |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Clear the DTCs and Operate the vehicle
within DTC Enable conditions in General
information. |
| 3. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this
time. |