Home › Heating,Ventilation, Air Conditioning › Blower › Control Panel

Blower › Control Panel: Repair procedures

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the center facia lower panel by pulling it using a screw driver after disconneting a clips. Avoid damaging retaining clips.

3.
Disconnect the connectors (A) from the center facia.

4.
Remove the heater & A/C controller temperature control cable (A).

5.
Remove the heater & A/C controller (A) after loosening 4 screws.

6.
Installation is the reverse order of removal.