An A/C refrigerant
pressure sensor is installed near the expansion valve. This sensor is used
by the ECM/PCM to evaluate A/C system pressure for the purposes of idle
speed correction, cooling/condenser fan control, and A/C compressor
control.
If signal is over 4.648V
under detecting condition, ECM/PCM sets P0533.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Short to power in signal
circuit |
| •
|
Faulty A/C Pressure
sensor |
|
Enable Conditions
|
| •
|
Ambient temperature > - 10.5 °C
(13°F) | |
Threshold Value
|
| •
|
Sensor output voltage >
4.648V | |
Diagnostic Time
|
|
MIL
ON Condition
|
|


| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of vehicle Repair" procedure.

▶ Go to " Power Circuit Inspection "
procedure. |
| 2. |
Disconnect the A/C pressure sensor
connector. |
| 4. |
Measure the voltage between terminal 3 of A/C
pressure sensor harness connector and chassis ground.

|
| 5. |
Is the measured voltage within specification
?

▶ Go to "Ground inspection"
procedure.

▶ Repair Open in power circuit and go to
"Verification of Vehicle Repair"
procedure. |
| GROUND CIRCUIT
INSPECTION |
| 2. |
Disconnect the A/C pressure sensor
connector. |
| 4. |
Measure the voltage between terminal 3 of A/C
pressure sensor harness connector and chassis ground. (Fig
A) |
| 5. |
Measure the voltage between terminal 3 and
terminal 1 of A/C pressure sensor harness connector.(Fig
B)
Specification : The Difference between
"A" and "B" is below 200mV.
|

|
| 6. |
Is the measured voltage within specification
?

▶ Go to "Signal circuit inspection"
procedure.

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure. |
| SIGNAL CIRCUIT
INSPECTION |
| 1. |
Voltage inspection
| (2) |
Disconnect the A/C pressure sensor
connector. |
| (4) |
Measure the voltage between terminal 2
of A/C pressure sensor harness connector and chassis
ground.
Specification : Approx.
0V
|

|
| (5) |
Is the measured voltage within
specification ?

▶ Go to "Component inspection"
procedure.

▶ Go to "Short in circuit inspection"
procedure. | |
| 2. |
Short in circuit inspection
| (2) |
Disconnect A/C pressure sensor connector
and ECM/PCM connector. |
| (3) |
Measure the resistance between terminal
2 and terminal 3 of A/C pressure sensor harness
connector.

|
| (4) |
Is the measured resistance within
specification ?

▶ Go to "Component inspection"
procedure.

▶ Repair Short in signal circuit and go
to "Verification of Vehicle Repair"
procedure. | |
| 1. |
A/C pressure sensor inspection
| (1) |
Key "OFF" and connect the
scantool. |
| (2) |
Connect the probe to A/C pressure sensor
signal and select the oscilloscope in the
menu. |
| (3) |
Check the change of Cwaveform with A/C
"ON" and A/C "OFF" after engine start.
Specification :
Pressure(psi)
|
14.7
|
100
|
200
|
300
|
470
|
Voltage(V)
|
0.5
|
1.25
|
2.13
|
3.00
|
4.50
|

|
| (4) |
Is the measured waveform of A/C pressure
sensor normal?

▶ Substitute with a known - good ECM/PCM
and check for proper operation. If the problem is corrected,
replace ECM/PCM and go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known - good A/C
pressure sensor and check for proper operation. If the problem
is corrected, replace A/C pressure sensor and go to
"Verification of Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Clear the DTCs and Operate the vehicle within
DTC Enable conditions in General
information. |
| 3. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |
Pressure(psi)
|
14.7
|
100
|
200
|
300
|
470
|
Voltage(V)
|
0.5
|
1.25
|
2.13
|
3.00
|
4.50
|