Check that the battery cables are
connected to the correct
terminals. |
| •
|
Disconnect the battery cables when the
battery is given a quick
charge. |
| •
|
Never disconnect the battery while the
engine is
running. | |
CHECK THE BATTERY TERMINALS AND FUSES
| 1. |
Check that the battery terminals are not loose
or corroded. |
| 2. |
Check the fuses for
continuity. |
INSPECT DRIVE BELT
| 1. |
Visually check the belt for excessive wear,
frayed cords etc.
If any defect has been found, replace the
drive belt.
|
Cracks on the rib side of a belt are
considered acceptable. If the belt has chunks missing from the
ribs, it should be replaced. |

|
| 2. |
Measure the drive belt tension and adjust
it.
Apply a force of 98N (10kg, 22lb), and measure
the deflection between the generator and the water pump
pulley.
DEFLECTION
New
belt
|
3.3 ~
3.7mm (0.1299 ~
0.1457in.)
|
Used
belt
|
4.2 ~
4.7mm (0.1654 ~
0.1850in.)
|
If the belt tension is not as specified,
adjust it.

| -
|
"New belt" refers to a belt which
has been used less than 5 minutes on a running
engine. |
| -
|
"Used belt" refers to a belt which
has been used on a running engine for 5 minutes or
more. |
| -
|
After installing a belt, check
that it fits properly in the ribbed
grooves. |
| -
|
Check with your hand to confirm
that the belt has not slipped out of the groove on the
bottom of the pulley. |
| -
|
After installing a new belt, run
the engine for about 5 minutes and recheck the belt
tension. | | |
VISUALLY CHECK GENERATOR WIRING AND LISTEN FOR
ABNORMAL NOISES
| 1. |
Check that the wiring is in good
condition. |
| 2. |
Check that there is no abnormal noise from the
generator while the engine is
running. |
CHECK DISCHARGE WARNING LIGHT CIRCUIT
| 1. |
Warm up the engine and then turn it
off. |
| 2. |
Turn off all
accessories. |
| 3. |
Turn the ignition switch "ON". Check that the
discharge warning light is lit. |
| 4. |
Start the engine. Check that the light is
lit.
If the light does not go off as specified,
troubleshoot the discharge light
circuit. |
INSPECT CHARGING SYSTEM
| VOLTAGE DROP TEST OF
GENERATOR OUTPUT WIRE |
This test determines
whether or not the wiring between the generator "B" terminal and the
battery (+) terminal is good by the voltage drop method.
PREPARATION
| 1. |
Turn the ignition switch to
"OFF". |
| 2. |
Disconnect the output wire from the generator
"B" terminal. Connect the (+) lead wire of ammeter to the "B"
terminal of generator and the (-) lead wire of ammeter to the output
wire. Connect the (+) lead wire of voltmeter to the "B" terminal of
generator and the (-) lead wire of voltmeter to the (+) terminal of
battery.

|
TEST
| 2. |
Turn on the headlamps and blower motor, and
set the engine speed until the ammeter indicates 20A.
And then, read the voltmeter at this
time. |
RESULT
| 1. |
The voltmeter may indicate the standard
value.
|
| 2. |
If the value of the voltmeter is higher than
expected (above 0.2V max.), poor wiring is suspected. In this case
check the wiring from the generator "B" terminal to the battery (+)
terminal. Check for loose connections, color change due to an
over-heated harness, etc. Correct them before testing
again. |
| 3. |
Upon completion of the test, set the engine
speed at idle.
Turn off the headlamps, blower motor and the
ignition switch. |
OUTPUT CURRENT TEST
This test determines
whether or not the generator gives an output current that is equivalent to
the normal output.
PREPARATION
| 1. |
Prior to the test, check the following items
and correct as necessary.
Check the battery installed in the vehicle to
ensure that it is good condition. The battery checking method is
described in the section "Battery".
The battery that is used to test the output
current should be one that has been partially discharged. With a
fully charged battery, the test may not be conducted correctly due
to an insufficient load.
Check the tension of the generator drive belt.
The belt tension check method is described in the section "Inspect
drive belt". |
| 2. |
Turn off the ignition
switch. |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Disconnect the generator output wire from the
generator "B" terminal. |
| 5. |
Connect a DC ammeter (0 to 150A) in series
between the "B" terminal and the disconnected output wire. Be sure
to connect the (-) lead wire of the ammeter to the disconnected
output wire.
|
Tighten each connection securely, as a
heavy current will flow. Do not rely on
clips. | |
| 6. |
Connect a voltmeter (0 to 20V) between the "B"
terminal and ground. Connect the (+) lead wire to the generator "B"
terminal and (-) lead wire to a good
ground. |
| 7. |
Attach an engine tachometer and connect the
battery ground cable. |
| 8. |
Leave the engine hood open.

|
TEST
| 1. |
Check to see that the voltmeter reads as the
same value as the battery voltage. If the voltmeter reads 0V, and
the open circuit in the wire between generator "B" terminal and
battery (-) terminal or poor grounding is
suspected. |
| 2. |
Start the engine and turn on the
headlamps. |
| 3. |
Set the headlamps to high beam and the heater
blower switch to HIGH, quickly increase the engine speed to 2,500
rpm and read the maximum output current value indicated by the
ammeter.
|
After the engine start up, the charging
current quickly drops.
Therefore, the above operation must be
done quickly to read the maximum current value
correctly. | |
RESULT
| 1. |
The ammeter reading must be higher than the
limit value. If it is lower but the generator output wire is in good
condition, remove the generator from the vehicle and test
it.
Limit value (90A alternator): 45A
min.
|
| •
|
The nominal output current value
is shown on the nameplate affixed to the generator
body. |
| •
|
The output current value changes
with the electrical load and the temperature of the
generator itself.
Therefore, the nominal output
current may not be obtained. If such is the case, keep
the headlamps on the cause discharge of the battery, or
use the lights of another vehicle to increase the
electrical load.
The nominal output current may not
be obtained if the temperature of the generator itself
or ambient temperature is too high.
In such a case, reduce the
temperature before testing
again. | | |
| 2. |
Upon completion of the output current test,
lower the engine speed to idle and turn off the ignition
switch. |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Remove the ammeter and voltmeter and the
engine tachometer. |
| 5. |
Connect the generator output wire to the
generator "B" terminal. |
| 6. |
Connect the battery ground
cable. |
REGULATED VOLTAGE TEST
The purpose of this test
is to check that the electronic voltage regulator controls voltage
correctly.
PREPARATION
| 1. |
Prior to the test, check the following items
and correct if necessary.
Check that the battery installed on the
vehicle is fully charged. The battery checking method is described
in the section "Battery".
Check the generator drive belt tension. The
belt tension check method is described in the section "Inspect drive
belt". |
| 2. |
Turn ignition switch to
"OFF". |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Connect a digital voltmeter between the "B"
terminal of the generator and ground. Connect the (+) lead of the
voltmeter to the "B" terminal of the generator. Connect the (-) lead
to good ground or the battery (-)
terminal. |
| 5. |
Disconnect the generator output wire from the
generator "B" terminal. |
| 6. |
Connect a DC ammeter (0 to 150A) in series
between the "B" terminal and the disconnected output
wire.
Connect the (-) lead wire of the ammeter to
the disconnected output wire. |
| 7. |
Attach the engine tachometer and connect the
battery ground cable.

|
TEST
| 1. |
Turn on the ignition switch and check to see
that the voltmeter indicates the following value.
If it reads 0V, there is an open circuit in
the wire between the generator "B" terminal and the battery and the
battery (-) terminal. |
| 2. |
Start the engine. Keep all lights and
accessories off. |
| 3. |
Run the engine at a speed of about 2,500 rpm
and read the voltmeter when the generator output current drops to
10A or less |
RESULT
| 1. |
If the voltmeter reading agrees with the value
listed in the regulating voltage table below, the voltage regulator
is functioning correctly. If the reading is other than the standard
value, the voltage regulator or the generator is
faulty.
REGULATING VOLTAGE TABLE
Voltage regulator ambient temperature °C
(°F)
|
Regulating voltage (V)
|
-20
(-4) 20 (68) 60 (140) 80
(176)
|
14.2 ~
15.4 14.0 ~ 15.0 13.7 ~ 14.9 13.5 ~
14.7
|
|
| 2. |
Upon completion of the test, reduce the engine
speed to idle, and turn off the ignition
switch. |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Remove the voltmeter and ammeter and the
engine tachometer. |
| 5. |
Connect the alternator output wire to the
generator "B" terminal. |
| 6. |
Connect the battery ground
cable. |