The pulse generator "A"
detects the speed of the end clutch retainer. The speed signal is used for
damper clutch control, hydraulic pressure control and incorrect gear
detection by PCM.
The pulse generator "B"
detects the speed of the transfer driven gear. The speed signal is used
for shift timing, hydraulic pressure control and incorrect gear detection
by PCM.
Pulse
generator A,B
|
Inspection
item
|
Standard
value
|
Senaor resistance
|
A: 1
terminal ~ 2 terminal
|
215 ~ 275
Ω
|
B: 1
terminal ~ 2 terminal
|
215 ~ 275
Ω
|
Output voltage (A,B)
|
1 terminal ~
ground
|
2.5 V ±
1.2V
|
2 terminal ~
ground
|
2.5
V
|