Home › Automatic Transaxle System › Automatic Transaxle Control System › Pulse Generator A

Automatic Transaxle Control System › Pulse Generator A: Repair procedures (A4AF3)

Replacement
1.
Remove the battery terminal.
2.
Remove the intake air hose and air clean assembly.
(Refer to the automatic transaxle - Removal/ installation procedure)
3.
Disconnect the sensor wire from the control cable mounting bracket.
4.
Remove the pulse generator A, B.
(1)
Disconnect the connector from the sensor.

(2)
Measure the pulse generator A, B resistance.

Standard value:
Pulse generator A: 245±30Ω/ 20°C(68°F)
Pulse generator B: 245±30Ω/ 20°C(68°F)

(3)
If the result isn't within the standard value, remove the pulse generator A, B.

5.
Measure the pulse generator A, B resistance.

Standard value
Pulse generator A : 245±30Ω/20°C(68°F)
Pulse generator B : 245±30Ω/20°C(68°F)

6.
If the result isn't within the standard value, replace the pulse generator A, B.
7.
Apply the ATF oil around the oil seal before installing the oil seal.
8.
Install the pulse generator A, B.

Tightening torque :
10~12Nm (100~120Kgf.cm, 7~8lb-ft)

9.
Connect the sensor wire to the control cable mounting bracket.
10.
Connect the pulse generator connector.
11.
Installation is the reverse of removal.