Home › Automatic Transaxle System (Automatic Transaxle) › Valve Body System › Pressure Control Solenoid Valve (PCSV)

Valve Body System › Pressure Control Solenoid Valve (PCSV): Description and Operation (A4AF3)

Description

-
SCSV-A/B/C (ON/OFF)
-
PCSV-A/B (Duty)
-
DCCSV (ON/OFF)
Function
-
Damper Clutch Control Solenoid Valve(DCCSV)
: Controlled by the PCM. A damper clutch operates by the DCCSV.
-
Shift Control Solenoid Valve-A (SCSV-A)
: Controlled by the PCM. It operates at 1st / 4th gear.
-
Shift Control Solenoid Valve-B (SCSV-B)
: Controlled by the PCM. It operates at 1st / 2nd gear.
-
Shift Control Solenoid Valve-C (SCSV-C)
: Controlled by the PCM. It operates at 3rd / 4th gear and reduces line pressure.
It controls the end clutch.
-
Pressure Control Solenoid Valve-A (PCSV-A)
: Controlled by the PCM. It controls the engaged pressure of the front clutch, end clutch, kick down brake and low & reverse brake.
-
Pressure Control Solenoid Valve-B (PCSV-B)
: Controlled by the PCM. It controls the engaged pressure of the rear clutch.
Item
Function
DC control solenoid valve
Makes the oil passage for damper clutch
Pressure control solenoid valve A
Makes the oil passage for K/D, E/C
Pressure control solenoid valve B
Makes the oil passage for R/C
Shift control solenoid valve A
Makes the oil passage at each gear
Shift control solenoid valve B
Makes the oil passage at each gear
Shift control solenoid valve C
Makes the oil passage for E/C
Torque reduction request sig.
Send torque reduction request signal to ECM

Features
Duty ratio
(Frequency)
-
PCVSV-A : 35Hz
-
PCVSV-B : 50Hz
Surge voltage

Structure

Pressure by duty ratio


Characteristics
Pin voltage
Output waveform
Solenoid valve resistance
Above 2.6Ω

Surge voltage
56V
IG "ON"
12~14V
(TCM Pin)

Solenoid Operation
Shift
SCSV-A
SCSV-B
SCSV-C
PCSV-A
PCSV-B
Remarks
1
ON
ON
OFF
ON
OFF

1→2A
OFF
ON
OFF
DUTY
OFF

2A
OFF
ON
OFF
OFF
OFF

2→3
OFF
OFF
OFF
DUTY
OFF

3
OFF
OFF
ON
OFF
OFF

3→4
ON
OFF
OFF
DUTY
OFF

4
ON
OFF
ON
OFF
OFF

4→3
OFF
OFF
OFF
DUTY
DUTY

4→2B
OFF
ON
ON
DUTY
DUTY

2B
OFF
ON
ON
ON
OFF

3→2A
OFF
ON
OFF
DUTY
OFF

2→1
ON
ON
OFF
ON
OFF

N→D2
OFF
ON
OFF
DUTY
DUTY

Fail safe
OFF
OFF
OFF
OFF
OFF