Home
›
Engine Electrical System
›
Ignition System
›
Ignition Coil
Ignition System › Ignition Coil: Repair procedures
Inspection
1.
Measure the primary coil resistance between terminals (+) and (-).
Standard value:
0.75Ω ± 15%
Replacement
1.
Remove the engine cover.
2.
Remove the ignition coil with bolt.
Tightening torque :
7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)
When removing the ignition coil connector, pull the lock pin(A) and push the clip(B).
3.
Installation is the reverse of removal.