If you release the
accelerator pedal suddenly after engine running about 4000 rpm, fuel
supply will stop for short period and the O2 sensor service data in the
Hi-Scan (Pro) will display values 200mV or lower. When you suddenly press
on the accelerator pedal down, the voltage will reach 0.6 ~ 1.0
V.
When you let the engine
idle again, the voltage will fluctuate between 200 mV or lower and 0.6 ~
1.0 V.
In this case, the
O2sensor can be determined as good. |