Home
›
Heating,Ventilation, Air Conditioning
›
Air conditioning System
›
Ambient sensor
Air conditioning System › Ambient sensor: Repair procedures
Inspection
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
[Specification]
Ambient temperature [°C(°F)]
Resistance between terminals 1and 2 (kΩ)
-10(14
164 ± 3%
0 (32)
97.5 ± 3%
10 (50)
59.6 ± 3%
20 (68)
37.5 ± 3%
4.
If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the ambient temperature sensor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front bumper. (Refer to BD group)
3.
Remove the ambient temperature sensor (A).
4.