Home › Engine Control/Fuel System › Engine Control System › Canister Close Valve (CCV)

Engine Control System › Canister Close Valve (CCV): Repair procedures

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the CCV connector.
3.
Measure resistance between the CCV terminal 1 and 2.
4.
Check that the resistance is within the specification.

Specification: Refer to "Specification"

5.
Disconnect the vapor hose connected with the canister from the CCV.
6.
Connect a vacuum pump to the nipple.
7.
Ground the CCV control line and apply battery voltage to the CCV power supply line.
8.
Apply vacuum and check the valve operation.

Specification: Vacuum maintained