Home › Heating,Ventilation, Air Conditioning › Air Conditioning System › Ambient Sensor

Air Conditioning System › Ambient Sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.

1. Sensor Ground
2. Ambient Sensor Signal

Specification
Ambient temperature
[°C(°F)]
Resistance between terminals 1and 2 (kΩ)
-30(-22)
507
-20(-4)
284.5
-10(14)
164.2
0 (32)
97.5
10 (50)
59.6
20 (68)
37.46
30(86)
24.18
40(104)
16
50(122)
10.83

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Loosen the mounting bolts and then remove the under cover (A).

3.
Disconnect the connector and then remove the ambient sensor (A).

4.