Home
›
Heating,Ventilation, Air Conditioning
›
Blower
›
Intake Actuator
Blower › Intake Actuator: Repair procedures
Inspection
1.
Ignition "OFF".
2.
Disconnect the intake actuator connector.
3.
Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 4.
4.
Verify that the intake actuator operates to the fresh position when connecting in the reverse.
1. -
2. –
3. Fresh
4. Recirculation
5. 5V (Vcc)
6. Feedback Signal
7. Sensor Ground
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater & blower unit assembly.
(Refer to HA group - "Heater Unit")
3.
Disconnect the Intake actuator connector (A).
4.
Loosen the mounting screw and then remove the intake actuator (B).
5.
Installation is the reverse order of removal.