Home › Heating,Ventilation, Air Conditioning › Air Conditioning System › Evaporator Temperature Sensor

Air Conditioning System › Evaporator Temperature Sensor: Repair procedures

Inspection
1.
Ignition "OFF".
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification
Evaporator core
temperature[°C(°F)]
Resistance[KΩ]
Voltage[V]
-10
17.93
3.22 ± 0.5
-5
14.22
2.94 ± 0.5
0
11.36
2.67 ± 0.5
5
9.14
2.39 ± 0.5
10
7.40
2.13 ± 0.5
15
6.02
1.88 ± 0.5
20
4.94
1.66 ± 0.5
25
4.066
1.45 ± 0.5
30
3.369
1.26 ± 0.5
35
2.85
1.1 ± 0.5
40
2.348
0.95 ± 0.5
45
1.975
0.83 ± 0.5
50
1.668
0.72 ± 0.5

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Using the screwdriver, remove the side cover(A).

3.
Loosen the mounting screw and then remove the crash pad lower cover(A)

4.
Disconnect the connector(A) and then remove the crash pad lower coner(B).

5.
Loosen the mounting screw and then remove the shower duct(A).

6.
Remove the evaporator temperature sensor (B), by pulling it after rorating 90° in a counter clock wise direction.

7.
Installation is the reverse order of removal.