Home
›
Heating,Ventilation, Air Conditioning
›
Air conditioning System
›
A.Q.S (Air Quality Sensor)
Air conditioning System › A.Q.S (Air Quality Sensor): Repair procedures
INSPECTION
1.
Check the output voltage of AQS between terminals 4 and 5.
Specification
Condition
Output signal
Fresh/recirculation
Normal condition
4 ~ 5V
Fresh
Hazardous gas detection
0 ~ 1V
Recirculation
REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front bumper under cover. (Refer to BD group).
3.
Remove the AQS (A) after loosening the mounting bolt.
4.
Installation is the reverse order of removal.