INSPECTION
TEMPERATURE CONTROL ACTUATOR(PASSENGER’S)
1.
Verify the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 4.
Verify that the temperture control actuator operates to the cool position when connecting in the reverse.

2.
Check the voltage between terminals 5 and 6.
Specification
Door position
Voltage (5-6)
Error detecting
Max. cooling
0.3 ± 0.15V
Low voltage :
0.1V or less
Max. heating
4.7 ± 0.15V
High voltage :
4.9V or more

It will feedback current position of actuator to controls.
TEMPERATURE CONTROL ACTUATOR(DRIVER’S)
1.
Verify the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 4.
Verify that the temperture control actuator operates to the cool position when connecting in the reverse.

2.
Check the voltage between terminals 5 and 6.
Specification
Door position
Voltage (5-6)
Error detecting
Max. cooling
0.3 ± 0.15V
Low voltage :
0.1V or less
Max. heating
4.7 ± 0.15V
High voltage :
4.9V or more

REPLACEMENT
TEMPERATURE CONTROL ACTUATOR(PASSENGER’S)
1.
Remove the glove box (Refer to BD group).

2.
Disconnect the temperature control actuator connector (A) after removing the air duct.
3.
Loosen the mounting screw and then remove the temperature control actuator (B).

4.
Installation is the reverse order of removal.
TEMPERATURE CONTROL ACTUATOR(DRIVER’S)
1.
Disconnect the negative (-) battery terminal.
2.
Disconnect the connector (C) of temperature control actuator.
3.
Loosen the mounting screw and then remove the temperature control actuator(D).

4.
Installation is the reverse order of removal.