TEMPERATURE CONTROL
ACTUATOR(PASSENGER’S)
| 1. |
Verify the temperature control actuator
operates to the hot position when connecting 12V to the terminal 3
and grounding terminal 4.
Verify that the temperture control actuator
operates to the cool position when connecting in the
reverse.

|
| 2. |
Check the voltage between terminals 5 and
6.
Specification
Door
position
|
Voltage
(5-6)
|
Error
detecting
|
Max.
cooling
|
0.3 ±
0.15V
|
Low
voltage : 0.1V or
less
|
Max.
heating
|
4.7 ±
0.15V
|
High
voltage : 4.9V or
more
|
It will feedback current position of actuator
to controls. |
TEMPERATURE CONTROL ACTUATOR(DRIVER’S)
| 1. |
Verify the temperature control actuator
operates to the hot position when connecting 12V to the terminal 3
and grounding terminal 4.
Verify that the temperture control actuator
operates to the cool position when connecting in the
reverse.

|
| 2. |
Check the voltage between terminals 5 and
6.
Specification
Door
position
|
Voltage
(5-6)
|
Error
detecting
|
Max.
cooling
|
0.3 ±
0.15V
|
Low
voltage : 0.1V or
less
|
Max.
heating
|
4.7 ±
0.15V
|
High
voltage : 4.9V or
more
|
|
TEMPERATURE CONTROL
ACTUATOR(PASSENGER’S)
| 1. |
Remove the glove box (Refer to BD
group).

|
| 2. |
Disconnect the temperature control actuator
connector (A) after removing the air
duct. |
| 3. |
Loosen the mounting screw and then remove the
temperature control actuator (B).

|
| 4. |
Installation is the reverse order of
removal. |
TEMPERATURE CONTROL ACTUATOR(DRIVER’S)
| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Disconnect the connector (C) of temperature
control actuator. |
| 3. |
Loosen the mounting screw and then remove the
temperature control actuator(D).

|
| 4. |
Installation is the reverse order of
removal. |