Verify that the mode control actuator operates
to the defrost position when connecting 12V to the terminal 3 and
grounding terminal. Verify that the mode control actuator operates
to the vent position when connecting in the
reverse.
2.
Check the voltage between terminals 5 and
6.
Door
position
Voltage
(5-6)
Error
detecting
Vent
0.3 ±
0.15V
Low
voltage : 0.1V or
less
Defrost
4.7 ±
0.15V
High
voltage : 4.9V or
more
* It will feedback current position of
actuator to controls.
REPLACEMENT
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the driver’s crush pad lower panel.
(Refer to BD group)
3.
Disconnect the mode control actuator connector
(A) after removing the air duct.
4.
Loosen the mounting screws and then remove the
mode control actuator (B).