The HECU supplies
battery power to the electric motor with a motor relay which is controlled
by the Electronic Control Unit(ECU). The electric motor pump supplies
hydraulic pressure to all wheel brake calipers by operating the piston
inside the pump.
The HECU monitors the
pump motor relay or fuse open, open or short in motor or motor lock and
then sets this code if a malfunction is detected. Warning lamp is turned
OFF unless fault is detected any more when the IG KEY is turned ON again,
and wheel speed is more than 15 km/h.
Item
|
Detecting
Condition
|
Possible cause
|
DTC Strategy
|
|
| •
|
Open or short of power supply circuit
(ABS1) |
|
Case1 (Stop monitor)
|
Monitoring
Period
|
| •
|
Stop monitor is active if the pump is
off i.e. not actuation and no
Slowdown. | |
Enable
Conditions
|
| •
|
A failure is detected if the pump motor
voltage > 2.0 V for more than 1
s. | |
Fail
Safe
|
| •
|
The return pump does not work
correct. |
| •
|
The ABS/ESC functions are inhibited,
reduced function of the EBD
system. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
Case2 (Pump run monitor)
|
Monitoring
Period
|
| •
|
The monitor is active if the pump is
switched on | |
Enable
Conditions
|
| •
|
A failure is detected if the pump motor
voltage < (battery voltage - 4.0 V) for more than
100ms. | |
Fail
Safe
|
| •
|
Pressure decrease (outlet valve) is no
longer possible. |
| •
|
The ABS/ESC functions are inhibited,
reduced function of the EBD
system. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
Case3 (Pump slowdown monitor)
|
Monitoring
Period
|
| •
|
Monitor is always active in the
transition "pump on → pump
off" | |
Enable
Conditions
|
| •
|
After the end of the actuation of the
motor relay, the pump motor is still in motion and is
generating a Voltage during it's slowdown. The generated UM is
monitored for a certain time on high level.
The time depends on the supply voltage
and is in the range of t = 30 ms to t = 125 ms. If the slow
down condition isn't met, the pump is activated again (see
actuation times below) and the slowdown time is measured
again. This is repeated for maximum n = 3 times.
If, after the last pump activation, the
pump motor slowdown time is still to short, a failure is
detected.
Actuation times:
1st actuation: 200 ms
2nd actuation: 1000 ms
3rd actuation: 3000
ms | |
Fail
Safe
|
| •
|
Pressure decrease (outlet valve) is no
longer possible. |
| •
|
The ABS/ESC functions are inhibited,
reduced function of the EBD
system. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
| 1. |
Connect scantool to Data Link
Connector(DLC) |
| 2. |
Ignition "ON" & Engine
"OFF". |
| 3. |
Select the "Actuation Test" mode on the
scantool. |
| 4. |
Inspect operating status of inlet valve with
Actuation Test.
Specification : It's normal if operating
sound is heard.
|

|
| 5. |
Does an inlet valve operate
normally?

▶ Fault is intermittent caused by faulty valve
or was repaired and HECU memory was not cleared. Go to the
applicable troubleshooting procedure.

▶ Go to "Component Inspection"
procedure. |
| Terminal & Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to "Power Circuit Inspection"
procedure. |
| Power Supply Circuit
Inspection |
| 2. |
Disconnect HECU
connector. |
| 4. |
Measure voltage between terminal "2" of the
HECU harness connector and chassis ground.
Specification : Approx.
B+
|

|
| 5. |
Is the measured voltage within
specifications?

▶ Go to "Ground Circuit Inspection"
procedure.

▶ Check for damaged harness and open or short
to GND between the battery terminal(+) and terminal "2" of the HECU
harness connector. Check for open or blown 40A ABS fuse referring to
"Circuit Diagram". Repair as necessary and then go to "Verification
of vehicle Repair" procedure. |
| Ground Circuit
Inspection |
| 2. |
Disconnect HECU
connector. |
| 3. |
Measure resistance between terminal "1" of the
HECU harness connector and chassis ground.
Specification : Approx. below 1
Ω
|

|
| 4. |
Is the measured resistance within
specifications?

▶ Go to "Component Inspection"
procedure.

▶ Check for damaged harness and poor
connection between terminal "1" of the HECU harness connector and
chassis ground. Repair as necessary and then go to "Verification of
vehicle Repair" procedure. |
| 3. |
Start and drive vehicle in gear and maintain
vehicle speed at approx. 15 km/h or more(9 mph or
more). |
| 4. |
Does warning lamp remain On?

▶ Substitute with a known-good HECU and check
for proper operation. If problem is corrected, replace HECU and then
go to "Verification of Vehicle Repair" procedure.

▶ Fault is intermittent caused by faulty HECU
or was repaired and HECU memory was not cleared. Go to the
applicable troubleshooting
procedure. |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode |
| 2. |
Using a scantool, clear
DTC. |
| 3. |
Operate the vehicle within DTC Detecting
Condition in General Information. |
| 4. |
Are any DTCs present ?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this
time. |