Home › Body Electrical System › Rear Window Defogger › Rear Window Defogger Timer

Rear Window Defogger › Rear Window Defogger Timer: Repair procedures

INSPECTION
1.
Condition 1
(1)
Alternator level high & defogger is OFF
(Defogger relay OFF and defogger activity OFF)
(2)
Defogger is activated (defogger switch ON)
(3)
Defogger outputs are turned ON
2.
Condition 2
(1)
Alternator level high & defogger is ON
(2)
Defogger switch Input pushed again or T1 delay has elapsed since defogger has been turned ON
(3)
Defogger outputs are turned OFF
3.
Condition 3
If alternator input is changed to low, defogger outputs should be turned OFF immediately.
4.