When the ignition switch
is ON or START position, voltage is applied to the ignition coil. Each
ignition coil consists of two coils. High tension leads go to each
cylinder from ignition coils. Ignition coils fire two spark plugs on every
power stroke (the cylinder under compression and the one on the exhaust
stroke). PCM provides ground to a switching circuit for energizing the
primary ignition coils. PCM uses the crankshaft position sensor and
camshaft position sensor signals to meet the timing of energizing coil.
When a primary ignition coil is energized or de-energized, the secondary
coil produces a high voltage spike to the attached spark
plugs.
Checking output signals
from ignition coils every 10 sec. under detecting condition, if signals
indicating open of short in the circuit are detected for more than 5 sec.,
PCM sets P0351. MIL(Malfunction Indication Lamp) turns on when the
malfunction lasts till consecutive 2 driving cycle.
Item
|
Detecting
Condition
|
Possible cause
|
DTC
Strategy
|
| •
|
Detects a short to ground, to battery or
open circuit | |
| •
|
Open or short in
harness |
|
EnableConditions
|
| •
|
NO DTC related to this
item |
| •
|
11V ≤ Battery voltage ≤
16V |
| •
|
The above conditions are met > 0.5
sec. | |
Threshold
value
|
|
DiagnosisTime
|
| •
|
Continuous
(More than 5 sec.failure for every 10
sec.test) | |
MIL On
Condition
|
|
Resistance (Ω)
|
Primary
Coil
|
Secondary
Coil
|
0.62 ± 10%
(Ω)
|
7.0 ± 15%
(kΩ)
|

| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Select "Diagnostic Trouble Codes(DTCs)" mode,
and then Press F4(DTAL) to check DTC's information from the DTCs
menu |
| 4. |
Read "DTC Status" parameter.

|
| 5. |
Is parameter displayed "Present
fault"?

▶ Go to "Terminal and Connector inspection"
procedure.

▶ Fault is intermittent caused by poor contact
in the sensor’s and/or PCM’s connector or was repaired and PCM
memory was not cleared. Thoroughly check connectors for looseness,
poorconnection, ending, corrosion, contamination, deterioration, or
damage. Repair or replace asnecessary and go to "Verification of
Vehicle Repair" procedure. |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure

▶ Go to " Power Circuit Inspection "
procedure. |
| 1. |
Check voltage
| (1) |
IG "OFF" and disconnect Ignition Coil
connector. |
| (2) |
IG "ON" and ENG
"OFF" |
| (3) |
Measure voltage between terminal 1 of
ignition coil harness connector and chassis
ground.
Specification : Approx.
B+
|

|
| (4) |
Is the measured voltage within
specification ?

▶ Go to "Control Circuit Inspection"
procedure.

▶ Check fuse connected to ignition coil
for open.
▶ Repair open in harness, and go to
"Verification of Vehicle Repair"
procedure. | |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
Check short to battery in
harness.
| (1) |
IG "OFF" and disconnect ignitioncoil
connector and PCM connector. |
| (2) |
Measure resistance between terminals 1
and 2 of ignition coil harness connector.

|
| (3) |
Is the measured resistance within
specification?

▶ Go to "Check short to ground in
harness" as follows.

▶ Repair short to battery in harness,
and go to "Verification of Vehicle Repair"
procedure. | |
| 2. |
Check short to ground in harness
| (1) |
IG "OFF" and disconnect ignition coil
connector and PCM connector. |
| (2) |
Measure resistance between terminal 2 of
ignition coil harness connector and chassis
ground.

|
| (3) |
Is the measured resistance within
specification?

▶ Go to "Check open in harness" as
follows.

▶ Repair short to ground in harness, and
go to "Verification of Vehicle Repair"
procedure. | |
| 3. |
Check open in harness
| (1) |
IG "OFF" and disconnect Ignition Coil
connector and PCM connector. |
| (2) |
Measure resistance between terminal 2 of
Ignition Coil harness connector and terminal 79 of PCM harness
connector.

|
| (3) |
Is the measured resistance within
specification?

▶ Go to "Component Inspection"
procedure.

▶ Repair open in harness, and go to
"Verification of Vehicle Repair"
procedure. | |
| 1. |
Check Ignition Coil
| (1) |
IG "OFF" and disconnect ignition coil
connector. |
| (2) |
Measure resistance between terminals 1
and 2 of ignition coil connector.(Component
side) |
| (3) |
Measure resistance between terminal 1 of
ignition coil connector and out terminal of secondary ignition
coil.
Specification :
Resistance (Ω)
|
Primary Coil (A)
|
Secondary Coil (B)
|
0.62 ± 10% (Ω)
|
7.0 ± 15%
(kΩ)
|

|
| (4) |
Is the measured resistance within
specification?

▶ Substitute with a known - good PCM and
check for proper operation
▶ If the problem is corrected, replace
PCM and go to "Verification of Vehicle Repair"
procedure.

▶ Substitute with a known - good
Ignition Coil and check for proper operation.
▶ If the problem is corrected, replace
Ignition Coil and go to "Verification of Vehicle Repair"
procedure.
|
There is a memory reset function
on scantool that can erase optional parts automatically
detected and memorized by PCM. After testing PCM on the
vehicle, use this function to reuse the PCM on the
others | | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode |
| 2. |
Press F4(DTAL) and confirm that "DTC Readiness
Flag" indicates "Complete". If not, drive the vehicle within
conditions noted in the freeze frame data or enable
conditions |
| 3. |
Read "DTC Status"
parameter |
| 4. |
Is parameter displayed "History(Not Present)
fault"?

▶ System performing to specification at this
time. Clear the DTC

▶ Go to the applicable troubleshooting