Home › Body Electrical System › Immobilizer System › Immobilizer Control Unit

Immobilizer System › Immobilizer Control Unit: Repair procedures

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Remove the driver crash pad lower panel(A) after removing side cover.(Refer to the BD group - " Crash pad ")

3.
Disconnect connectors of lower panel.
4.
Disconnect the 5P connector of the SMARTRA unit and then remove the SMARTRA unit (B) mounted on the left side cowl cross bar. after loosening a shear bolt (A).

5.
Installation is the reverse of removal procedure.