Home
›
Heating,Ventilation, Air Conditioning
›
Blower
›
Blower Unit
Blower › Blower Unit: Repair procedures
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad.(Refer to BD group-Crash pad)
3.
Disconnect the connectors from the intake actuator, the blower motor and power mosfet.
4.
Remove the cowl cross bar assembly.(Refer to BD group-Crash pad)
5.
Remove the heater and blower unit.
6.
Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.
Make sure that there is no air leaking out of the blower and duct joints.
7.
Installation is the reverse order of removal.