| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Remove the power mosfet. Measure
drain-to-sauce resistance of the power mosfet.

Resistance (Drain-Sauce)
|
Subject
|
1
|
2
|
Power mosfet
|
Drain
|
+
|
―
|
Sauce
|
―
|
+
|
Section
|
Normal
|
∞
|
Approx 3M Ω
|
Short
|
Approx 0 ~ 300 Ω
|
Approx 0 ~ 300 Ω
|
Open
|
∞
|
∞
|
|
| 3. |
If the measured resistance is not
specification, replace the power
mpsfet. |
| 4. |
If measured resistance is specification,
install power mosfet and ignition switch ON. Measure the voltage
between blower motor terminals by operating control switch
manually. |
| 5. |
Select the control switch to raise voltage
until high speed.

Specification
Fan
|
Motor
Voltage
|
Manual
|
First speed
|
3.8 ± 0.5V
|
Second speed
|
5.0 ± 0.5V
|
Third speed
|
6.2 ± 0.5V
|
Fourth speed
|
7.4 ± 0.5V
|
Fifth speed
|
8.6 ± 0.5V
|
Sixth speed
|
9.8 ± 0.5V
|
Seventh speed
|
11.0 ± 0.5V
|
eighth speed
|
Battery(+)
|
|
| 6. |
If the measured voltage is not
specification, substitute with a known-good power mosfet and check
for proper operation. |
| 7. |
If the problem is corrected, replace the
power mosfet. |
| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Disconnect the power mosfet connector (A) at
the connecting part between heater and blower unit.

|
| 3. |
Remove the power mosfet (B) after loosening
the mounting screws.

|
| 4. |
Installation is the reverse order of
removal. | |