Temperature control
actuator located at heater unit. It contains temp motor that changes temp
door position and potentiometer that monitors position of temp door.
Temperature control actuator regulates the temperature by the procedure as
follows. Signal from control unit adjusts position of temp door by
operating temp motor and then temperature will be regulated by the
hot/cold air ratio decided by position of temp door. In operation,
potentiometer delivers temp door position transformed into voltage value
to A/C ECU .
The ECM sets DTC B1245
if there is an open circuit or poor connection in the driver air mix
actuator signal harness.
Item
|
Detecting
Condition
|
Possible
Cause
|
DTC Strategy
|
|
| •
|
Poor connection of connected
part |
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness |
| •
|
Faulty DR Air Mix
actuator | |
Threshold value
|
|
Detecting time
|
|
FAIL SAFE
|
| •
|
setting temperature :
63°F-76.1°F
fix at max. cooling
position |
| •
|
setting temperature :
77°F-89.6°F
fix at max. heating
position | |
※ Voltage value of Air
Mix potentiometer as a function of temp door position.
Door
position
|
Voltage
|
Error
Detecting Condition
|
Max. cool
|
0.3±0.15V
|
Undervoltage : 0.08V or
less
|
Max.warm
|
4.7±0.15V
|
Overvoltage : 4.9V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |

Fig.1) The current data in abnormal
state
Fig.2) DTC B1245
Monitor the "DR AIR MIX potentiometer"
Parameter on the Scantool. While operating temp
switch. |
| 4. |
Are the DTC B1245 present and is parameter
of "DR AIR MIX potentiometer" fixed?
※ Parameter of "DR AIR MIX potentiometer"
will be fixed at d at 100%(or any value above 90%), or 0% (or any
value below 10%), if there is any fault in DR AIR MIX
actuator.
|

|
▶ Go to "Inspection
& Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. ▶
Thoroughly check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or damage.
Repair or replace as necessary and then go to "Verification of
Vehicle Repair"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals.
Faults can also be caused by interference
from other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to "W/Harness
Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for open
in harness |
| 2. |
Disconnect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "6" of
DR Air Mix actuator and terminal "B18" of A/C control
unit.
Specification :
Approx. 0 Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Check for
short to ground in harness" procedure.
|
|

|
▶ Check for open in
signal harness. Repair as necessary and go to "Verification
of Vehicle Repair"
procedure.
|
|
| ■ Check for
short to ground in harness |
| 2. |
Disconnect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "6" of
DR Air Mix actuator and chassis ground.
Specification :
Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Power
circuit Inspection" procedure.
|
|

|
▶ Check for short
to ground in signal harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| Power Supply Circuit
Inspection |
| ■ Check for open
in harness |
| 2. |
Connect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "5" of
DR Air Mix actuator and terminal "B1" of A/C Control
Unit.
Specification :
Approx. 0 Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Check for
short in harness " procedure.
|
|

|
▶ Check for open in
harness. Repair as necessary and go to "Verification of
Vehicle Repair"
procedure.
|
|
| ■ Check for
short in harness |
| 2. |
Connect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "5" of
DR Air Mix actuator and chassis ground.
Specification :
Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Component
Inspection" procedure.
|
|

|
▶ Check for short
in harness. Repair as necessary and go to "Verification of
Vehicle Repair"
procedure.
|
|
| 2. |
Disconnect DR Air Mix
actuator. |
| 3. |
Measure voltage value between terminal "B1"
of A/C control unit and chassis ground.

|
| 4. |
Is the measured voltage within
specifications?
|

|
▶ Go to "Check DR
Air Mix actuator" procedure.
|
|

|
▶ Substitute with a
known-good A/C Control Unit and check for proper
operation. If the problem is
corrected, replace A/C Control Unit and then go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR Air
Mix actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Air Mix
actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Air Mix actuator and (-) terminal to terminal
4. |
| (4) |
Verify that the temperature actuator
operates to the cool
position. |
| (5) |
Verify that the temperature actuator
operates to the warm position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go to
"Check potentiometer" procedure.
|
|

|
▶ Substitute
with a known-good actuator and check for proper
operation. If the problem is corrected, replace actuator
and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Air Mix
actuator. |
| (3) |
Measure voltage between terminal "6"
and "7" of DR Air Mix actuator while operating the temp
switch.
Specification : Refer the specifications in
fig3)
|

Fig.3) Specifications : Voltage value of air mix
potentiometer as a function of temp door position
Door
position
|
Voltage
|
Erro
Detecting Condition
|
Max.cool
|
0.3±0.15V
|
Undervoltage
: 0.08V or less
|
Max.warm
|
4.7±0.15V
|
Overvoltage :
4.9V or
more
|
|
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶ Check
connectors for looseness, poor connection, bending,
corrosion, contamination, deterioration, or damage.
Repair or replace as necessary and then go to
"Verification of Vehicle Repair"
procedure
|
|

|
▶ Substitute
with a known-good actuator and check for proper
operation. If the problem is corrected, replace actuator
and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on
the scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|