The mode control
actuator mounted on heater unit adjusts position of mode door by operating
Direction Motor in accordance with signal of A/C control unit. Pressing
mode select switch makes the mode control actuator shift in order of vent→
B/L → floor → mix.
The ECM sets DTC B2409
if the direction motor dosen’t move to intended position within 40sec(The
ECM attempts to move the temp door for a 2 second duration at a frequency
of 3 times every 20 seconds before storing a DTC.)
Item
|
Detecting
Condition
|
Possible
Cause
|
DTC Strategy
|
|
| •
|
Poor connection of connected
part |
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness. |
| •
|
Faulty DR Direction
actuator |
|
Threshold value
|
|
Detecting time
|
|
FAIL SAFE
|
| •
|
Setting mode : VENT
Fix at VENT
position |
| •
|
Setting mode : Except
VENT
Fix at DEF
position | |
※ Voltage value of
Direction potentiometer as a function of position of mode
switch
Door
position
|
Voltage
|
Error
Detecting Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or
less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "DR DIRECTION POTENTIO"
parameter on the scantool. While operating mode switch.

Fig.1) The current data in abnormal
state
Fig.2) DTC
B2409 |
| 4. |
Are the DTC B2409 present and is parameter
of "DR DIRECTION POTENTIO" fixed?
※ There is any fault in DR Direction Motor.
If the parameter of "DR DIRECTION POTENTIO" is 10% or less on "VENT"
mode, or If the parameter is 90% or more on "DEF" mode.
|

|
▶ Go to "Inspection
& Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. ▶
Thoroughly check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or damage.
Repair or replace as necessary and then go to "Verification of
Vehicle Repair"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals.
Faults can also be caused by interference
from other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to "W/Harness
Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for open
in harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "3" of
DR Direction actuator and terminal "20" of A/C control
unit. |
| 4. |
Measure resistance between terminal "4" of
DR Direction actuator and terminal "19" of A/C control
unit.
Specification : Approx.
0 Ω
|

|
| 5. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Check for
short to ground in harness" procedure.
|
|

|
▶ Check for open in
signal harness. Repair as necessary and go to "Verification
of Vehicle Repair"
procedure.
|
|
| ■ Check for
short to ground in harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "3,4" of
DR Direction Motor and chassis ground.
Specification :
Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to "Component
Inspection " procedure.
|
|

|
▶ Check for short
to ground in signal harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR
Direction Actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Direction
Actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Direction Actuator and (-) terminal to
terminal 4. |
| (4) |
Verify that the temperature actuator
operates to the DEF position. |
| (5) |
Verify that the temperature actuator
operates to the VENT position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go to
"Check potentiometer" procedure.
|
|

|
▶ Substitute
with a known-good actuator and check for proper
operation. If the problem is corrected, replace actuator
and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Direction
Actuator. |
| (3) |
Measure voltage between terminal "5"
and "6" of DR Direction Actuator while operating the temp
switch.
Specification : Refer the specifications in
fig3)
|

Fig.3) Specifications : Voltage value of Direction
potentiometer as a function of temp door position
Door
position
|
Voltage
|
Erro
Detecting Condition
|
VENT
|
0.3±0.15V
|
Undervoltage
: 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage :
4.92V or
more
|
|
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶ Go to
"Check A/C Control Unit" procedure.
|
|

|
▶ Substitute
with a known-good actuator and check for proper
operation. If the problem is corrected, replace actuator
and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Connect A/C Control
Unit. |
| 3. |
Measure voltage between terminal "19" and
"20" of A/C Control Unit while operating the temp
switch.
Specification :
Approx. 12V
|

|
| 4. |
Is the measured voltage within
specifications?
|

|
▶ Check connectors
for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure
|
|

|
▶ Substitute with a
known-good A/C Control Unit and check for proper
operation. If the problem is
corrected, replace A/C Control Unit and then go to
"Verification of Vehicle Repair"
procedure.
|
|
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on
the scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|