Connector
Terminal
|
Specifications
|
Conditions
|
No
|
Description
|
1
|
Ground(Pump)
|
Current range : Min-10 A Max-20 ~ 39 A
|
Always
|
4
|
Ground(Valve,ECU)
|
Current range : Min-2.5 A Max-5 ~ 15 A
|
Always
|
2
|
Supply Voltage(Pump)
|
Battery voltage
|
Always
|
3
|
Supply Voltage(Valve)
|
26
|
Wheel Sensor Voltage(FL)
|
Battery voltage
|
IG On
|
9
|
Wheel Sensor VoltageFR)
|
6
|
Wheel Sensor Voltage(RL)
|
8
|
Wheel Sensor Voltage(RR)
|
5
|
Wheel Sensor Signal(FL)
|
Voltage(High) : 0.89~1.26
V Voltage(Low) : 0.44~0.63
V
|
Running
|
10
|
Wheel Sensor Signal(FR)
|
27
|
Wheel Sensor Signal(RL)
|
29
|
Wheel Sensor Signal(RR)
|
11
|
Diagnosis Input/Output
|
Voltage(High) : 0.8 * IG ON more Voltage(Low)
: 0.2 * IG ON lower
|
HI-SCAN Communication
|
28
|
Ignition
|
Battery voltage
|
KEY On/Off
|
31
|
ESC Passive Switch
|
Voltage(High) : 0.6 * IG ON more Voltage(Low)
: 0.4 * IG ON lower
|
Switch On/Off
|
13
|
Hand Brake Switch
|
Voltage(High) : 0.7 * IG ON more Voltage(Low)
: 0.3 * IG ON lower
|
Switch On/Off
|
35
|
CAN High
|
not communication:2.5 ± 0.5
V communication :

|
IG ON
|
14
|
CAN Low
|
30
|
Brake Light Switch
|
voltage(High) : 0.8 * IG ON more voltage(Low)
: 0.3 * IG ON lower
|
BRake On/Off
|