Verify that the mode control actuator operates
to the defrost position when connecting 12V to the terminal 3 and
grounding terminal. Verify that the mode control actuator operates
to the vent position when connecting in the
reverse.
2.
Check the voltage between terminals 5 and
6.
Door
position
Voltage
(5-6)
Error
detecting
Vent
0.3 ±
0.15V
Low
voltage : 0.1V or
less
Defrost
4.7 ±
0.15V
High
voltage : 4.9V or
more
* It will feedback current position of
actuator to controls.
Replacement
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the driver’s crash pad lower panel.
(Refer to BD group-Crash pad)
3.
Disconnect the mode control actuator connector
(A) after removing the air duct.
4.
Loosen the mounting screws and then remove the
mode control actuator (B).