The mode control
actuator mounted on heater unit adjusts position of mode door by operating
Direction Motor based on signal of A/C control unit. Pressing mode select
switch makes the mode control actuator shift in order of vent→ B/L → floor
→ mix.
The ECM sets DTC B1250
if there is a short to power in the DR Direction actuator signal
harness.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness | |
Threshold
value
|
|
Detecting
time
|
|
FAIL
SAFE
|
| •
|
Setting mode : VENT
Fix at VENT
position |
| •
|
Setting mode : Except VENT
Fix at DEF
position | |
※ Voltage value of
Direction potentiometer as a function of position of mode
switch.
Door position
|
Voltage
|
Error Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "DR DIRECTION POTENTIO" parameter
on the scantool. While operating mode switch.

Fig.1) The current data in abnormal
state
Fig.2) DTC
B1250 |
| 4. |
Are the DTC B1250 present and is parameter of
"DR DIRECTION POTENTIO" fixed ?
※ Parameter of "DR DIRECTION POTENTIO" will be
fixed at 100%(or any value above 90%), or 0% (or any value below
10%), if there is any fault in DR Direction actuator.
|

|
▶ Go to
"Inspection & Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. ▶
Thoroughly check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or damage.
Repair or replace as necessary and then go to "Verification of
Vehicle Repair"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for short in
harness |
| 2. |
Disconnect DR Direction
potentiometer. |
| 3. |
Measure resistance between terminal "6" and
"7" of DR Direction potentiometer.
Specification
: Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Ground circuit Inspection" procedure.
|
|

|
▶ Check for
short to power harness in signal harness. Repair as necessary
and go to "Verification of Vehicle Repair"
procedure.
|
|
| Ground Circuit
inspection |
| ■ Check for open in
ground harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "5" of DR
Direction Actuator and chassis ground.
Specification
: Approx. 0 Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Component Inspection " procedure.
|
|

|
▶ Check for
open in ground harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR Direction
Actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Direction
Actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Direction Actuator and (-) terminal to
terminal 4. |
| (4) |
Verify that the temperature actuator
operates to the DEF position. |
| (5) |
Verify that the temperature actuator
operates to the VENT position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go
to "Check potentiometer" procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Direction
Actuator. |
| (3) |
Measure voltage between terminal "5" and
"6" of DR Direction Actuator while operating the temp
switch.
Specification : Refer
the specifications in fig3)
|

Fig.3) Specifications : Voltage value of Direction
potentiometer as a function of temp door position
Door
position
|
Voltage
|
Erro Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 010V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
|
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶
Check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or
damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair"
procedure
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic Trouble
Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|