Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Ambient sensor

Air conditioning System › Ambient sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
Specification
Ambient temperature [°C(°F)]
Resistance between terminals 1and 2 (kΩ)
-20(-4.0)
0 (32)
25(77.0)
50(122.0)
80(176.0)
271.1 ± 3%
95.1 ± 3%
30.0 ± 3%
37.5 ± 3%
3.83 ± 3%

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front bumoer under cover.
3.
Remove the connector ambient temperature sensor.
4.
Loosen the mounting bolt and then remove the ambient temperature sensor.
5.
Installation is the reverse order of removal.