Home › Heating,Ventilation, Air Conditioning › Controller › Heater & A/C Control Unit(Full Automatic)

Controller › Heater & A/C Control Unit(Full Automatic): Troubleshooting

Self-diagnosis
1.
Self-diagnosis process
The F.A.T.C. module self test feature will detect electrical malfunction and provide error codes for system components with suspected failures.

DTC data can be retrieved from the control panel directly or from the DLC using the Hi-Scan Pro.
2.
How to read self-diagnostic code
After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format.
Fault code
Fault code
Fail description
Control unit
DTC
00
-
Normal
11
B1234
In-car temperature sensor open
12
B1233
In-car temperature sensor short
13
B1238
Ambient temperature sensor open
14
B1237
Ambient temperature sensor short
15
B1202
Water temperature sensor open
16
B1203
Water temperature sensor short
17
B1242
Evaporator temperature sensor open
18
B1241
Evaporator temperature sensor short
19
B1245
Temperature control actuator feed back open (Drive's)
19
B1246
Temperature control actuator feed back short (Drive's)
20
B2406
Temperature control actuator failure
21
B1249
Mode control actuator open
21
B1250
Mode control actuator short
22
B2409
Mode control actuator failure
25
B1208
Intake potentiometer open
25
B1209
Intake potentiometer short
26
B2408
Intake potentiometer failure
32
B1204
Temperature control actuator open (Passenger's)
32
B1205
Temperature control actuator short (Passenger's)
33
B2415
Temperature control actuator failure

3.
Fault code display
(1)
Continuance operation

(2)
Step operation

(3)
STEP operation

4.
If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
5.
Fail safe
NO.
ITEM
FAIL SAFE
1
In-car temperature sensor
Control with the valve of 25°C (77°F)
2
Ambient temperature sensor
Control with the valve of 20°C (67°F)
3
Evaporator temperature sensor
Control with the valve of -2°C (28.4°F)
4
Temperature sensor
Control with the valve of -2°C (28.4°F)
5
Temperature control actuator
If temperature setting 17°C - 24.5°C. Fix at maximum cooling position.
If temperature setting 25°C - 32°C. Fix at maximum heating position.
6
Mode control actuator
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
7
Intake control actuator
Fix fresh position, while seleting fresh mode.
Fix recifculation position, while selecting recirculation mode.
8
Photo sensor
None correction