Home › Body Electrical System › Trunk lid › Trunk Lid Release Actuator

Trunk lid › Trunk Lid Release Actuator: Repair procedures

Inspection
1.
Remove the trunk lid trim panel. (Refer to the Body group - trunk lid)
2.
Disconnect the 3P connector from the actuator.

3.
Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.